Unit installation
C-5
TYPICAL SYSTEM CONNECTIONS
AD2096A TO AD2150/2350
AD2150/2350
RS232 PORTS
MONITORS
12 34 5
123
ALARMS RELAY
KEYBOARDS
23 45
CAMERAS
CODE
120V
60Hz
BWS BWS BWS BWS
2468101214161820222426283032
135791113151719212325272931
AD2096A
SELECTS ALARM GROUP #
1-64, 65-128, 129-192 etc....
NORMALLY OPEN/CLOSED
POSITION FOR ALARM INPUTS
1-8, 9-16, 17-24 etc...
1
2
3
45
6
7
8
TERMINAL BOX 2113-0019-01
BROWN
(GRD)
GREEN
RED
GREEN
BROWN
(GRD)
RED
1
2
3
45
6
7
8
NOTE: FOR DISTANCES GREATER THAN 7' BETWEEN UNITS,
TERMINAL BOXES MUST BE USED. THE MAXIMUM
DISTANCE BETWEEN THE BOXES IS 1000' (330m)
USING SHIELDED, 18 AWG CABLE.
TYPICAL AD2096A CONNECTIONS TO AD2150/2350 SWITCHERS:
WHEN THE UNITS ARE LESS THAN 7' APART, USE CABLE 6003-0047-02
WHEN DISTANCES EXCEED 7', TERMINAL BOXES MUST BE USED
6003-0047-02
2113-0019-01
TERMINAL BOX
6003-0047-02
CABLE 6003-0047-02
FOR DIRECT CONNECTIONS
UP TO 7 FEET