Model AD2096A Alarm Interface Unit Installation and Operating Instructions This manual describes the installation and operating procedures for the American Dynamics AD2096A Alarm Interface Unit. The AD2096A Alarm Interface Unit, when used with American Dynamics Matrix Switching Systems, automatically calls specified cameras and preset scenes to specified monitors when contacts are activated external to the system.
The software/firmware furnished with this equipment is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software/firmware is furnished to the purchaser under a license for use on a single system. Information furnished by SENSORMATIC is believed to be accurate and reliable.
AMERICAN DYNAMICS The installation of this product should be made by qualified service personnel and should conform to all local codes. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
CONTENTS Page DESCRIPTION .............................................................................. 1 FEATURES .................................................................................... 1 INSTALLATION............................................................................ 1 Mounting.................................................................................... 1 SETUP ............................................................................................
AD2096A ALARM INTERFACE UNIT SELECT ABCDEFGH POWER ALARM ABCDEFGH 1 A A 25 26 A 49 C O M INPUT OUTPUT 2 A A 50 A 3 4 A A 27 A A 28 A 51 A 5 52 A A A 30 31 32 33 34 35 A A 55 56 57 58 59 A 53 A 7 A 29 A 6 54 A A 8 A 9 A A A 10 A A A 11 12 A A A A 36 A 60 A 13 14 15 16 17 A A 37 38 39 40 41 A A 61 62 63 64 A A A A A A A A A 18 19 A 42 A 20 21 22 23 A A A A A 43 44 45 46 47 A A A A A 24 A 48 A 120V 60Hz A N N C O
ALARM INTERFACE UNIT AD2096A SETUP Table 2 - S2, Input Type Setup 0 = OFF (Normally Open, NO) 1 = ON (Normally Closed, NC) Three 8-position DIP switches are used for AD2096A setup. The first two switches, S1 and S2, are located on the rear panel (see Figure 1, page 1). The top switch, S1, identifies the block of 64 alarm contacts (out of a possible 1024) which are connected to the AD2096A.
AD2096A ALARM INTERFACE UNIT CONNECTIONS Use NEC Class 2 wiring only for all external connector pin connections. The wiring should also conform to all local codes. ! RS-232 Connectors Alarm Inputs The two RS-232 COM connectors on the rear panel of the AD2096A are 8-pin, modular type RJ-45 connectors. One (1) 8-pin terminal box 2113-0019-01 and one (1) 7-foot modular cable 6003-0047-02 are supplied with each AD096A for connections to these ports.
ALARM INTERFACE UNIT AD2096A OPERATION Alarm Response Operation Power Sources Each alarm input signal is assigned an alarm contact number (ACN) by the AD2096A. The setting of DIP switch S1 (see page 2) determines the range of ACN’s for each AD2096A. Depending on the Matrix Switching System capabilities, a maximum of 1024 alarm contacts (ACN’s) can be programmed for alarm event response by that system. Power is supplied via the appended 3-wire power cord. Power consumption is approximately eight watts.
Typical System Connections
TYPICAL SYSTEM CONNECTIONS AD2096A TO AD1650 Series TYPICAL AD2096A CONNECTIONS TO AD1650 SWITCHERS: WHEN THE UNITS ARE LESS THAN 7' APART, USE CABLE 6003-0047-02 WHEN DISTANCES EXCEED 7', TERMINAL BOXES MUST BE USED NORMALLY OPEN/CLOSED POSITION FOR ALARM INPUTS 1-8, 9-16, 17-24 etc... 1 SELECTS ALARM GROUP # 1-64, 65-128, 129-192 etc....
TYPICAL SYSTEM CONNECTIONS AD2096A TO AD1995 FOR ALL CONNECTIONS TO AD1995 CPU, TERMINAL BOXES MUST BE USED. THE MAXIMUM DISTANCE BETWEEN THE BOX AND THE AD1995 CONNECTOR IS 1000' (330m) USING SHIELDED, 18 AWG CABLE. NORMALLY OPEN/CLOSED POSITION FOR ALARM INPUTS 1-8, 9-16, 17-24 etc... 1 SELECTS ALARM GROUP # 1-64, 65-128, 129-192 etc....
TYPICAL SYSTEM CONNECTIONS AD2096A TO AD1996 TYPICAL AD2096A CONNECTIONS TO AD1996 CPU: WHEN THE UNITS ARE LESS THAN 7' APART, USE CABLE 6003-0047-02 WHEN DISTANCES EXCEED 7', TERMINAL BOXES MUST BE USED NORMALLY OPEN/CLOSED POSITION FOR ALARM INPUTS 1-8, 9-16, 17-24 etc... 1 2 3 4 5 6 SELECTS ALARM GROUP # 1-64, 65-128, 129-192 etc....
TYPICAL SYSTEM CONNECTIONS AD2096A TO AD2150/2350 TYPICAL AD2096A CONNECTIONS TO AD2150/2350 SWITCHERS: WHEN THE UNITS ARE LESS THAN 7' APART, USE CABLE 6003-0047-02 WHEN DISTANCES EXCEED 7', TERMINAL BOXES MUST BE USED NORMALLY OPEN/CLOSED POSITION FOR ALARM INPUTS 1-8, 9-16, 17-24 etc... 1 SELECTS ALARM GROUP # 1-64, 65-128, 129-192 etc....
TYPICAL SYSTEM CONNECTIONS Cascading Multiple AD2096A Units TYPICAL CONNECTIONS TO CASCADE MULTIPLE AD2096A UNITS: WHEN THE UNITS ARE LESS THAN 7' APART, USE MODULAR CABLE 6003-0047-02 WHEN DISTANCES EXCEED 7', TERMINAL BOXES MUST BE USED SELECT 1 2 3 4 5 A A A A A 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ON OFF ABCDEFGH POWER A A 25 26 27 28 29 30 ALARM A A A A A 31 32 33 34 35 36 A A A A A A A A A A A A 37 38 39 40 41 42 43 44 45 46 47 48 A A ON OFF
TYPICAL SYSTEM CONNECTIONS AD2010DBVL Module to AD2096A to AD1996 18-AWG CABLE 1 2 3 A A A SELECT ABCDEFGH 1 2 A 4 5 A A 3 4 5 A A A A 6 ALARM CONTACT A 6 A 7 8 9 10 11 12 A A A A A 13 14 15 16 17 18 A A A A A A 19 20 21 22 23 24 A A POWER 25 26 27 28 29 30 31 32 33 34 35 36 A A A A A 37 38 39 40 41 42 43 44 45 46 47 48 A A ALARM ABCDEFGH C O M INPUT OUTPUT A A A A A A A A A A A A A A A A 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
Index
INDEX AD2096A Alarm Input Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Alarm Relay Output Connection . . . . . . . . . . . . . . . . . . . . . 3 Alarm Response Operation . . . . . . . . . . . . . . . . . . . . . . . . . 4 Baud Rate Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Block Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Cascading Multiple Units . . . . . . . . . . . . . . . . . . . . . . . . . .
DECLARATION OF CONFORMITY According to ISO/IEC Guide 22 and EN45014 Manufacturer’s Name: Sensormatic Electronics Corporation Manufacturer’s Address: 1 Blue Hill Plaza 2nd Floor Pearl River, New York, 10965 USA Declares, that the product listed below: Name/Type: Alarm Interface Unit Model Number: AD2096-1 complies with all applicable directives as demonstrated by conformance to the following Product Specifications: Safety: EN 60950: 1992 EMC: EN 50130-4: 1995 EN 55022: 1994 , Class B EN 61000-3-2
SPECIFICATIONS Models AD2096A: 120 VAC, 50/60 Hz AD2096-1: 230 VAC, 50/60 Hz Electrical Input: AD2096A AD2096-1 - 120 VAC, 50/60Hz, 8 W - 230 VAC, 50/60 Hz, 40 mA Alarm Inputs Contact Inputs: 64 inputs, each with contact and separate ground Open Circuit Voltage: 5.0 VDC Closed Circuit: Maximum Current: 0.