Installation manual
40
MegaPower
TM
48+
Video Connections in a Multi-Matrix System
The video connections made in a multi-matrix system will depend on the operation mode that is being used.
In all following sections, the maximum number of trunk video connections are shown and by connecting in this manner,
the maximum number of full cross point switched monitor outputs can be achieved. It should be noted that if the number
of full cross point switched monitor outputs is lower, only this number of trunk video connections need to be made.
Mode 1 Configurations
Mode 1: Primary Matrix with 1 Secondary Matrix
Consult the figure below in order to connect video inputs and outputs to the system. The 16 monitor outputs from the
secondary matrix must be connected to video inputs 1-16 on the primary matrix. Sixteen full cross point switched
monitor outputs are available by connecting monitors to video outputs 1-16 on the primary matrix.
PRIMARY MATRIX
CONNECT MONITOR OUTPUTS 1-16
ON SECONDARY MATRIX A TO VIDEO
INPUTS 1-16 ON PRIMARY MATRIX
MONITORS 1-16
(PORT REFS. X1-X16)
SECONDARY MATRIX A
CAMERAS 1-48
(PORT REFS. A1-A48)
CAMERAS 49-80
(PORT REFS. X17-X48)