Specifications

ADJ Products, LLC - www.adj.com - Vizi Roller Beam 2R Instruction Manual Page 36 ADJ Products, LLC - www.adj.com - Vizi Roller Beam 2R Instruction Manual Page 37
Vizi Roller Beam 2R System Menu
Rec Controller - The Vizi Roller Beam 2R features an integrated DMX
recorder. Preprogrammed scenes can be transmitted to the xture via
any DMX compliant controller. This function allows those scenes to
be stored in to the xture’s built-in memory and
then subsequently used to create the user-dened programs.
Vizi Roller Beam 2R Error Codes
When power is applied, the unit will automatically enter a
“reset/test” mode. This mode brings all the internal motors to a
home position. If there is an internal problem with one or more
of the motors an error code will ash in the display in the form
of “XXer”, “XX” will represent a function number. For example,
when the display shows “03Er,” it means there is some type of
error with the channel 3 motor. If there are multiple errors during
the start-up process they will all ash in the display. For exam-
ple: if the xtures has errors on channel 1 and channel 3 all at
the same time, you will see the error message ash “01Er”, and
“03Er repeated 5 times.
If an error does occur during the initial start-up procedure the
xture will self-generate a second reset signal and try to realign
all the motors and correct the errors, if the errors persist after a
second attempt a third attempt will be made.
If after a third attempt all the errors have not been corrected the
xture will make the following determinations:
1) 3 or more errors - The xture cannot function properly with
three or more errors therefore the xture will place itself in a
stand-by mode until subsequent repairs can be made.
2) Less than 3 errors - If the xture has less than 3 errors, there-
fore most other functions will work properly. The xture will
attempt to operate normally until the errors can be corrected by
a technician. The errors in question will remain ashing in the
display as a reminder of internal errors.
03Er – TILT movement error:
This message will appear after a xture reset, if the tilt mag-
netic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a stepper motor failure (defective motor or a
defective motor IC drive on the main PCB).
05Er – COLOR WHEEL error:
This message will appear after a xture reset, if the head’s mag-
netic-indexing circuit malfunctions (sensor failed or magnet is