Specifications
ADJ Products, LLC - www.adj.com - Vizi Roller Beam 2R Instruction Manual Page 36 ADJ Products, LLC - www.adj.com - Vizi Roller Beam 2R Instruction Manual Page 37
Vizi Roller Beam 2R System Menu
Rec Controller - The Vizi Roller Beam 2R features an integrated DMX
recorder. Preprogrammed scenes can be transmitted to the xture via
any DMX compliant controller. This function allows those scenes to
be stored in to the xture’s built-in memory and
then subsequently used to create the user-dened programs.
Vizi Roller Beam 2R Error Codes
When power is applied, the unit will automatically enter a
“reset/test” mode. This mode brings all the internal motors to a
home position. If there is an internal problem with one or more
of the motors an error code will ash in the display in the form
of “XXer”, “XX” will represent a function number. For example,
when the display shows “03Er,” it means there is some type of
error with the channel 3 motor. If there are multiple errors during
the start-up process they will all ash in the display. For exam-
ple: if the xtures has errors on channel 1 and channel 3 all at
the same time, you will see the error message ash “01Er”, and
“03Er repeated 5 times.
If an error does occur during the initial start-up procedure the
xture will self-generate a second reset signal and try to realign
all the motors and correct the errors, if the errors persist after a
second attempt a third attempt will be made.
If after a third attempt all the errors have not been corrected the
xture will make the following determinations:
1) 3 or more errors - The xture cannot function properly with
three or more errors therefore the xture will place itself in a
stand-by mode until subsequent repairs can be made.
2) Less than 3 errors - If the xture has less than 3 errors, there-
fore most other functions will work properly. The xture will
attempt to operate normally until the errors can be corrected by
a technician. The errors in question will remain ashing in the
display as a reminder of internal errors.
03Er – TILT movement error:
This message will appear after a xture reset, if the tilt mag-
netic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a stepper motor failure (defective motor or a
defective motor IC drive on the main PCB).
05Er – COLOR WHEEL error:
This message will appear after a xture reset, if the head’s mag-
netic-indexing circuit malfunctions (sensor failed or magnet is