User Instructions Rev. 9/07 American DJ® 4295 Charter Street Los Angeles CA. 90058 www.americandj.com American DJ® - www.americandj.
American DJ ® Accu Scan 250™ Table of Contents General Information.....................................................................4 Features.........................................................................5 Safety Precautions......................................................................6 Handling Precautions..................................................................7 Discharge Lamp Warnings..........................................................7 Registration.................
Accu Scan 250™ • • • • • • • • • • • • • • • • • Features Micro-Stepping Motors for Smooth Color and Gobo Transitions DMX-512 Protocol Compatible (Uses Eight DMX Channels) Independent Gobo and Color Wheels 7 Rotating Gobos w/ Shake, 1 Dichroic and 1 Beveled gobo + Spot - All Replaceable 9 Colors, Plus White - With Rainbow RDMX - Lets you set the DMX address from any DMX Controller 3 Operating Modes - Master/Slave; Stand Alone; Sound Active Internal Microphone ZB-MSD250 Discharge Lamp, 250w 2000 Hou
Accu Scan 250™ Handling Precautions Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact American DJ®. During operation the housing may become extremely hot. Avoid touching the unit with bare hands while in use.
Accu Scan 250™ Controls and Functions Accu Scan 250™ Controls and Functions 1. Mirror - This is a highly reflective surface mirror specifically designed to optimize and enhance beam output. Never use glass cleaners that contain ammonia to clean the surface of the mirror (such as Windex). 2. Lens Assembly - This high quality lens is a fully focusing. Focus the lens by manually turning the lens in a clockwise or counter-clockwise direction until the desired effect is achieved. 1 2 3.
Accu Scan 250™ Controls and Functions cords may cause the unit to overheat or malfunction. Voltage may vary from venue to venue, when connecting this unit to a power supply be sure to connect to a matching power outlet. Never use this fixture if the ground prong has been removed or broken off. The ground prong is designed to reduce the risk of fire or electrical shock in the event the unit suffers from an internal short. Fuse Holder - This housing stores a 8 amp (4 amp 220v) GMA protective fuse.
Accu Scan 250™ REMOTE CONTROL INPUT SOUND INPUT OUTPUT REMOTE CONTROL INPUT SOUND INPUT Set Up OUTPUT conductor shielded cable (This cable may be purchased at almost all professional sound and lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and cannot be split. POWER POWER Notice: Be sure to follow figures two and three when making your own DMX512 DMX+,DMX-,COMMON cables.
Accu Scan 250™ System Menu Accu Scan 250™ System Menu ADDRESS MENU 0 ADDR A001---Axxx 1 TEST 2 PLAY 4 RESE 5 TIME 6 7 10 RPAN RTLT MIC 11 DISP 12 SPEC T-01~T-XX RUN AUDI AUTO ALL SCAN COLR GOBO SHTR LIFE LAMP CLMP ON/OFF ON/OFF M-XX VALU D ON FLIP RDMX SPOT DFSE VER ADJU STEP 13 EDIT SCXX REC.
Accu Scan 250™ System Menu ON/OFF - When “On” is chosen it will reverse the tilt. MIC MENU M-01-M-70 - With this function you can make the internal mic more or less sensitive to sound. DISPLAY MENU VALU (DMX-512 Value) - Display the DMX-512 value of each channel. D ON (Display On) - Turns digital display on and off. FLIP - “Flips” the digital display 180º. SPEC MENU RDMX - On/Off With this function you are able to change the DMX address via external controller. See pages 25-26.
Accu Scan 250™ System Menu 3. The display will show “T0-1”, “1” stands for the channel number 1, if you press the UP button until “T0-3” is displayed, the unit will test the color channel, changing the color one by one and showing the rainbow effect with different speeds. 4. Press MODE/ESC to exit. PLAY MENU - Accu Scan 250™ 3. Tap the UP button until “AUTO” is displayed, press ENTER. 4. Now you can choose between “AUDI” or “RUN”. “AUDI” is sound active mode and “RUN” is the built-in program.
Accu Scan 250™ GOBO motor. System Menu With this function you can reset the gobo wheel Accu Scan 250™ System Menu 2. Tap the UP button until “TIME” is displayed, press ENTER. 3. Tap the UP button until “LAMP” is displayed, press ENTER. 1. Access the main menu. 4. The display shows the running time of the lamp. 2. Tap the UP button until “RESE” is displayed, press ENTER. 5. Press MODE/ESC to return to the main menu. 3. Tap the UP button until “GOBO” is displayed.
Accu Scan 250™ System Menu 1. Access the main menu. 2. Tap the UP button until “RTLT” is displayed, press ENTER. 3. Press ENTER, the display will show “ON/OFF”. 4. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate this function. 5. Press ENTER to confirm. 6. Press MODE/ESC to return to the main menu. MIC MENU - MIC - The internal microphone can be made more or less sensitive. Accu Scan 250™ System Menu 4. The display should show “D-00”.
Accu Scan 250™ System Menu 7. Press MODE/ESC to return to the main menu. SPEC MAIN MENU - RDMX With this function you are able to change the DMX address via any DMX controller. This function is factory set to “ON” already. 1. Access the main menu by pressing MODE/ESC. 2. Tap the UP button until “SPEC” is displayed, press ENTER. 3. Tap the UP button until “RDNI I” is displayed, press ENTER. 4. The display will show “ON/OFF”.
Accu Scan 250™ System Menu 5. Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function. 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. When you exit this function, the unit will begin to reload data. VER - Use this function to display the Software version of the unit. 1. Access the main menu. 2. Tap the UP button until “SPEC” is displayed, press ENTER. Accu Scan 250™ System Menu 7.
Accu Scan 250™ Editing Program EDIT - This feature allows you to write and store a preset show into the fixtures internal memory (EEPROM) via the control panel or via the external controller. This show can then be recalled at anytime without a controller. Accu Scan 250™ Editing Program Editing procedure 1: Using the control board only. 1. Access the main menu. 2. Tap the UP button until “EDIT” is displayed. Press ENTER. RUN - With this function you can run your pre-made pro- 3.
Accu Scan 250™ Editing Program Accu Scan 250™ Editing Program editing, the display will change to the next scene automatically. Editing procedure 2: Using an external controller. 13. Repeat steps 3-12 to edit other scenes, you can edit and save 48 scenes maximum. 1. Access the main menu. 14. Press MODE/ESC to exit, now you have edited and saved scenes using the control board. The number of steps can be defined under “Step” and the scenes can be called up under “Run”.
Accu Scan 250™ Operation Operating Modes: The Accu Scan 250™ can operate in three different modes. This next section will detail the differences in the operating modes. • Stand alone mode The unit will react to sound, chasing through the built-in programs. • Master/Slave mode You can daisy chain up to 16 units together to get a synchronized light show without the need of an external controller. The units will react to sound chasing through the several built-in programs.
Accu Scan 250™ Fuse & Lamp Replacement Caution: Always replace with the exact same type lamp and fuse, unless otherwise specified by an authorized American DJ® service technician. Replacing with anything other than the specified part can damage your unit and will void your manufactures warranty. Warning: If you continue to blow lamps or fuses, STOP using the unit. Contact customer support for further instructions, you may have to return the unit for servicing.
Accu Scan 250™ Channel Value Function 1 0 - 255 PAN 2 0 - 255 TILT 3 0 - 199 COLOR 0 - 19 20 - 39 40 - 59 60 - 79 80 - 99 100 - 119 120 - 139 140 - 159 160 - 179 180 - 199 200 - 255 4 0 - 13 14 - 27 28 - 41 42 - 55 56 - 69 70 - 83 84 - 97 98 - 115 116 - 135 136 - 155 156 - 175 176 - 195 196 - 215 216 - 235 236 - 255 DMX Traits WHITE RED BLUE GREEN YELLOW MAGENTA ORANGE PURPLE PINK LIGHT BLUE RAINBOW EFFECT SLOW FAST GOBO SPOT ROTATING GOBO 1 (metal) ROTATING GOBO 2 (metal) ROTATING GOB
Accu Scan 250™ Channel Value 7 Function RESET/INTERNAL PROGRAMS 0 - 19 20 - 39 40 - 79 80 - 84 85 - 87 88 - 90 91 - 93 94 - 96 97 - 99 100 - 119 120 - 139 140 - 159 160 - 179 180 - 199 200 - 219 220 - 239 240 - 255 8 DMX Traits cont.
Accu Scan 250™ Cleaning Fixture Cleaning: Due to fog residue, smoke, and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use we recommend cleaning on a monthly basis. Periodic cleaning will ensure longevity, and crisp output. 1.
Accu Scan 250™ Model: Voltage*: Lamp: Dimensions: Colors: Gobos: Weight: Fuse: Duty Cycle: DMX: Sound Active: Working Position: Warranty: Specifications Accu Scan 250™ 120v/60Hz or 230v/50Hz ZB-MSD250/2, 250w 2000 Hours 9”(L) x 11.5”(W) x 22.5”(H) 228mm x 292mm x 571mm 9 Plus White 7 Rotating + Spot - All Replaceable 25mm Outside/ 20mm Viewable 30 Lbs. / 13.6 kgs.