Brochure
Standard Series Glass & Solid
Door Laboratory Refrigerators
The all-new Standard Series Glass & Solid Door
Laboratory Refrigerators are purpose built for
scientific and medical applications. To improve
performance over past solid door general purpose
units, the new Standard Series Glass & Solid
Door Laboratory Refrigerators feature a digital
microprocessor temperature controller allowing for
the precise temperature management necessary for
critical samples and supplies.
The all-new temperature display and alarm module
offers product security with a monitoring and alarm
system. Real-time sample simulated temperatures
are constantly displayed and supported by audible/
visual high and low temperature alarms. Remote
alarm dry contacts and an access port are provided
to simplify connections to existing facility monitoring
systems.
A forced air directional refrigeration system provides
superior temperature uniformity and recovery after
door openings. An automatic cycle-defrost design
prevents product damaging temperature spikes.
10 11
Standard Series Glass & Solid Door
Laboratory Refrigerators
• Microprocessor temperature controller
• Digital temperature display
• Audible and visual high and low temperature alarms
• Remote alarm contacts
• Adjustable operating temperature: 1°C – 10°C
• Magnetic door gasket for positive seal
• Swivel casters (3 ½”)
• Heavy duty door handle
• LED interior lights are safety shielded and switch controlled
• Probe access port (⅜”)
• Powder coated steel white interior and exterior
• High density urethane foam cabinet insulation
• CFC-free refrigerant (R134a), foam insulation and packaging
• One year parts and labor warranty, plus an additional four year
compressor parts warranty
• UL/C-UL listed
ABT-LS-12
ABT-LS-23
ABT-LS-16 ABT-LS-36
Model Cu. Ft. Defrost Doors Shelves W” D” H” RL H.P. Amps
ABT-LS-12 12 Cycle 1 Swing Glass 3 Adj 25 29 ¾ 65 ¾ R134a
⅜
6
ABT-LS-16 16 Cycle 1 Swing Glass 3 Adj 25 29 ¾ 79 R134a
⅜
6
ABT-LS-23 23 Cycle 1 Swing Glass 4 Adj 26 ⅞ 29 ¾ 81 ¾ R134a
⅜
6
ABT-LS-26 26 Cycle 1 Swing Glass 4 Adj 28 ⅝ 36 ½ 81 ¾ R134a
⅜
6
ABT-LS-33 33 Cycle 2 Slide Glass 8 Adj 39 ⅝ 33 ¼ 81 ¾ R134a
⅜
6
ABT-LS-36 36 Cycle 2 Swing Glass 8 Adj 39 ⅝ 34 ¾ 81 ¾ R134a
½
9
ABT-LS-47 47 Cycle 2 Slide Glass 8 Adj 54 33 ¼ 81 ¾ R134a
½
7
ABT-LS-49 49 Cycle 2 Swing Glass 8 Adj 54 34 ¾ 81 ¾ R134a
½
7
ABT-LS-69 69 Cycle 3 Slide Glass 12 Adj 81 33 ¼ 81 ¾ R134a
¾
10
ABT-LS-72 72 Cycle 3 Swing Glass 12 Adj 81 34 81 ¾ R134a
¾
10
*Height Includes Casters
Model Cu. Ft. Defrost Doors Shelves W” D” H” RL H.P. Amps
ABT-SLS-12 12 Cycle 1 Swing Solid 3 Adj 25 29 ¾ 65 ¾ R134a
⅜
6
ABT-SLS-16 16 Cycle 1 Swing Solid 3 Adj 25 29 ¾ 79 R134a
⅜
6
ABT-SLS-23 23 Cycle 1 Swing Solid 4 Adj 26 ⅞ 34 ¾ 81 ¾ R134a
⅜
6
ABT-SLS-26 26 Cycle 1 Swing Solid 4 Adj 28 ⅜ 36 ½ 81 ¾ R134a
⅜
6
ABT-SLS-36 36 Cycle 2 Swing Solid 8 Adj 39 ⅝ 34 ¾ 81 ¾ R134a
½
9
ABT-SLS-49 49 Cycle 2 Swing Solid 8 Adj 54 34 ¾ 81 ¾ R134a
½
7
ABT-SLS-72 72 Cycle 3 Swing Solid 12 Adj 81 34 81 ¾ R134a
¾
10
*Height Includes Casters
The Standard Laboratory Refrigerators take a large step
forward in performance from past general purpose units;
offering a digital temperature display and alarm module
coupled with a microprocessor temperature controller.
ଂC/ଂF convertible
temperature display