Standard Series Glass & Solid
Door Laboratory Refrigerators
The all-new Standard Series Glass & Solid Door
Laboratory Refrigerators are purpose built for
scientific and medical applications. To improve
performance over past solid door general purpose
units, the new Standard Series Glass & Solid
Door Laboratory Refrigerators feature a digital
microprocessor temperature controller allowing for
the precise temperature management necessary for
critical samples and supplies.
The all-new temperature display and alarm module
offers product security with a monitoring and alarm
system. Real-time sample simulated temperatures
are constantly displayed and supported by audible/
visual high and low temperature alarms. Remote
alarm dry contacts and an access port are provided
to simplify connections to existing facility monitoring
systems.
A forced air directional refrigeration system provides
superior temperature uniformity and recovery after
door openings. An automatic cycle-defrost design
prevents product damaging temperature spikes.
10 11
Standard Series Glass & Solid Door
Laboratory Refrigerators
Microprocessor temperature controller
Digital temperature display
Audible and visual high and low temperature alarms
Remote alarm contacts
Adjustable operating temperature: 1°C – 10°C
Magnetic door gasket for positive seal
Swivel casters (3 ½”)
Heavy duty door handle
LED interior lights are safety shielded and switch controlled
Probe access port (”)
Powder coated steel white interior and exterior
High density urethane foam cabinet insulation
CFC-free refrigerant (R134a), foam insulation and packaging
One year parts and labor warranty, plus an additional four year
compressor parts warranty
UL/C-UL listed
ABT-LS-12
ABT-LS-23
ABT-LS-16 ABT-LS-36
Model Cu. Ft. Defrost Doors Shelves W” D” H” RL H.P. Amps
ABT-LS-12 12 Cycle 1 Swing Glass 3 Adj 25 29 ¾ 65 ¾ R134a
6
ABT-LS-16 16 Cycle 1 Swing Glass 3 Adj 25 29 ¾ 79 R134a
6
ABT-LS-23 23 Cycle 1 Swing Glass 4 Adj 26 29 ¾ 81 ¾ R134a
6
ABT-LS-26 26 Cycle 1 Swing Glass 4 Adj 28 36 ½ 81 ¾ R134a
6
ABT-LS-33 33 Cycle 2 Slide Glass 8 Adj 39 33 ¼ 81 ¾ R134a
6
ABT-LS-36 36 Cycle 2 Swing Glass 8 Adj 39 34 ¾ 81 ¾ R134a
½
9
ABT-LS-47 47 Cycle 2 Slide Glass 8 Adj 54 33 ¼ 81 ¾ R134a
½
7
ABT-LS-49 49 Cycle 2 Swing Glass 8 Adj 54 34 ¾ 81 ¾ R134a
½
7
ABT-LS-69 69 Cycle 3 Slide Glass 12 Adj 81 33 ¼ 81 ¾ R134a
¾
10
ABT-LS-72 72 Cycle 3 Swing Glass 12 Adj 81 34 81 ¾ R134a
¾
10
*Height Includes Casters
Model Cu. Ft. Defrost Doors Shelves W” D” H” RL H.P. Amps
ABT-SLS-12 12 Cycle 1 Swing Solid 3 Adj 25 29 ¾ 65 ¾ R134a
6
ABT-SLS-16 16 Cycle 1 Swing Solid 3 Adj 25 29 ¾ 79 R134a
6
ABT-SLS-23 23 Cycle 1 Swing Solid 4 Adj 26 34 ¾ 81 ¾ R134a
6
ABT-SLS-26 26 Cycle 1 Swing Solid 4 Adj 28 36 ½ 81 ¾ R134a
6
ABT-SLS-36 36 Cycle 2 Swing Solid 8 Adj 39 34 ¾ 81 ¾ R134a
½
9
ABT-SLS-49 49 Cycle 2 Swing Solid 8 Adj 54 34 ¾ 81 ¾ R134a
½
7
ABT-SLS-72 72 Cycle 3 Swing Solid 12 Adj 81 34 81 ¾ R134a
¾
10
*Height Includes Casters
The Standard Laboratory Refrigerators take a large step
forward in performance from past general purpose units;
offering a digital temperature display and alarm module
coupled with a microprocessor temperature controller.
ଂC/ଂF convertible
temperature display