Owner's manual

Page 9 American Access Systems / Security Brands, Inc.
Door Monitor
If the door is open, other than during a valid entry, a “Door Open” message is recorded. If the unit is connected to
a printer, the message is also sent immediately. If, during a valid entry, the Door Monitor senses that the door has
been opened and closed prior to expiration of the latch timer, the latch relay will immediately be reset; this feature is
sometimes called “anti-tailgate.”
Bell
When activated, the unit sends an ASCII “bell” signal to the PC (if monitoring real-time transactions) or Serial Printer (if
connected). This will cause a PC and some serial printers to “beep.”
Remote Inactive
The unit may be made inactive remotely using a switch. While inactive the LED blinks Red slowly, and no cards will
be granted access. An appropriate message will be recorded and will be sent to the PC (if monitoring real-time
transactions) or Printer (if connected).
Remote Open
(Also called Request to Exit). The passageway may be opened remotely using a push button, switch or contact
output from an Exit PIR designed for access-controlled doors. Remote Open functions even when the unit is in
an inactive mode. An appropriate message will be recorded and will be sent to the PC (if monitoring real-time
transactions) or Printer (if connected).
User Dened
This selection allows the user to dene the action taken when the input is activated. The user may create the
transaction text message to be recorded and decide if the 11-65000 is to grant access and if the Bell signal is to be
sent.
To change the denition of an input, choose 5 (System Conguration) from the Main Menu. Then, from the System
Conguration Menu, choose 1, 2, or 3 depending whether input 1, 2, or 3 is to be redened. Then select the desired
input function from the Input Denition Menu.