Owner manual

Page 15 American Access Systems / Security Brands, Inc.
“309”
SubMode 309 (QUIET MODE)
NOTE: From the factory, QUIET MODE is enabled.
DESCRIPTION: If you want to hear the good or bad beeps at your desk when an access code is entered at the slave
keypad you can disable the quiet mode. This sub-mode can be toggled on or off by pressing:
(MASTER CODE) + 309(*) + (MASTER CODE)
(*) 1 BEEP AND RED LED ON = FEATURE ENABLED
(*) 2 BEEP AND RED LED OFF = FEATURE DISABLED
“400”
SubMode 400 (PRINT AUDIT TRAIL)
NOTE: THE UNIT MUST BE INTERFACED TO A PRINTER TO INVOKE THIS SUBMODE.
DESCRIPTION: The PROX 2000 II is capable of storing up to 1000 transactions in it’s history buffer. Once the unit
reaches 1000 transactions the unit will roll over and overwrite the rst transaction unless the buffer is cleared (see
submode 499).
To print out the history buffer enter the 4 digit “MASTER CODE” followed by submode “400”.
(MASTER CODE) + 400
The unit will continually print out all transactions from rst transaction to last. Should you make an entry error, simply
press the * key and reenter the correct data. Once the unit has nished it will respond with a GOODBEEP and exit from
the program mode. To halt printing simply turn the printer off.
“401”
SubMode 401 (PRINT OUT ALL CURRENT ACCESS CARDS)
NOTE: THE UNIT MUST BE INTERFACED TO A PRINTER TO USE THIS SUBMODE.
DESCRIPTION: This sub-mode is used to print out all access cards in the system.
To print out all access cards enter the 4 digit “MASTER CODE” followed by submode “401”.
(MASTER CODE) + 401
“402”
SubMode 402 (PRINT AUDIT TRAIL ON SPECIFIC CARD)
NOTE: THE UNIT MUST BE INTERFACED TO A PRINTER TO INVOKE THIS SUBMODE.
DESCRIPTION: This sub-mode is used to print out the audit trail (history) of a specic card. The unit goes through the
1000 code history buffer and nds when the specic card has been used and prints the times and dates.
To print out the history of a specic card enter the 4 digit “MASTER CODE” followed by submode “402” followed by the
“SPECIFIC CARD”.
(MASTER CODE) + 402 + (SPECIFIC CODE)
Example: To print out the history of code 13156 enter:
“MASTER CODE” + 402 + 13156
1 - 9600 baud
2 - 4800 baud
3 - 2400 baud
4 - 1200 baud
“403”
SubMode 403 (SET PRINTER BAUD RATE)
The default baud rate is 9600. To program in a different baud rate choose from these 4 choices and put in the
number 1 thru 4.
(MASTER CODE) + 403 + (1,2,3 OR 4)
Example: To change to 2400 baud:
MASTER CODE” + 403 +