SK-A CP SK-ACP User/Installation Manual
SK-ACP Installation & Operating Manual COPYRIGHT© 2001 SECURA KEY a division of SOUNDCRAFT INC.
SK-ACP Installation & Operating Manual SK-ACP TABLE OF CONTENTS 1. INTRODUCTION ................................................................................................. 1 Introduction to SK-ACP Card ID Numbers and Facility Codes 2. INSTALLATION ................................................................................................... 4 Physical Installation Wiring Power and Batteries Readers Inputs Outputs RS-232 Connections RS-485 Connections 3. PROGRAMMING THE SK-ACP WITH SK-NET™ .
SK-ACP Installation & Operating Manual
SK-ACP Installation & Operating Manual INTRODUCTION T he SK-ACP Advanced Control Panel is a highly sophisticated, yet simple to use, two door access control unit. The unit accepts readers of almost any technology, with a Wiegand output up to 40 bits, including Proximity, Touch Card, Wiegand, Magnetic Stripe, Bar Code, Optical, and Biometric. Each of the two passageways controlled by the unit is completely independent of the other and is configured, programmed and viewed separately.
SK-ACP Installation & Operating Manual
SK-ACP Installation & Operating Manual SETTING THE FACILITY (SYSTEM) CODE IMPORTANT Before programming or using a new unit, the correct Facility Code must be set. When power is first applied, or when the reset button is pushed (see Figure 3) the LED on each of the two readers will flash red and green alternately.
SK-ACP Installation & Operating Manual INSTALLATION CAUTION SHOULD BE TAKEN NOT TO TOUCH CIRCUIT BOARD OR ELECTRONIC COMPONENTS PRIOR TO AND DURING INSTALLATION TO AVOID ELECTRO-STATIC DISCHARGE (ESD) DAMAGE. INSTALLING THE SK-ACP 1. Select a location for the SK-ACP unit that is secure and sheltered from weather and extreme humidity. Choose a location that facilitates access to power and is reasonably close to the doors that are to be controlled (no further than 500 feet). 2.
SK-ACP Installation & Operating Manual WIRING The SK-ACP unit is organized so that the wiring for door #1 is on the right side of the panel and the wiring for door #2 is on the left side of the panel (see figure 3). For ease of installation and servicing, plug-in terminal blocks are provided.
SK-ACP Installation & Operating Manual POWER & BATTERIES The SK-ACP unit must be connected to a source of low voltage power. The SK-ACP should NOT be connected to the same power supply that is providing power to an electric lock or strike. We recommend that you use the Secura Key SK-ACP-PS, which includes a 24 VDC, 500 mA transformer and a 12VDC, 1.9AH standby battery, to power the SK-ACP. Terminals 7 & 8 on plug “J7” must be connected to 16.5 to 24 volts, AC or DC.
SK-ACP Installation & Operating Manual FIGURE 4 7
SK-ACP Installation & Operating Manual programmed using SK-NET™ software (see SK-NET™ manual, section 5.33) NOTE: Two MOVs (metal-oxide varistors) are provided with each SK-ACP. These must be installed between the “Common” and either the “Normally Open” or the “Normally Closed” terminals where power to the electric lock or strike is being switched (See Figures 6 and 7).
SK-ACP Installation & Operating Manual Installation of Metal Oxide Varistor with Electric Strike N.O. ACCESS CONTROL COM UNIT N.C. + _ µ INSTALL MOV HERE LOCK POWER SUPPLY AC or DC STRIKE Install the enclosed 40-volt MOV (Metal Oxide Varistor) across the relay contacts in the access control unit, as shown. The Access Control Unit must have its own power supply. FIGURE 6 Installation of Metal Oxide Varistor with Magnetic Lock N.O. ACCESS CONTROL COM UNIT N.C.
SK-ACP Installation & Operating Manual RS-485 The RS-485 bus is used to link multiple SK-ACP units into a network. Where two or more SK-ACPs are linked, you must run cable between the “J8” plugs on each panel. Terminals 1 & 2 must be a twisted pair of wires. SUGGESTED CABLE IS Belden 1585A. Terminal 3, if used, may be connected to one conductor of another twisted pair. (Terminal 3 is a “signal ground”. If used, this must be an insulated conductor and it should NOT be connected to earth ground.
SK-ACP Installation & Operating Manual FACTORY SETTINGS When shipped from the factory, the SK-ACP has the following settings: Facility Code None* All Cards Time Zone 0 (void) No Limited Use Cards Settings Latch timer = 1 Second APB Timer = 0 Minutes (off) Baud Rate = 38,400* Reader ID = (none) Password = 12345* Date = Undetermined* Time = Undetermined* Time Zones APB = Timed Hard* Date Restrictions = None 0 = Always Void 1 = Always Valid (no restriction) 2 = Mon - Fri, 8am - 5:30pm 3 = Mon - Fri, 6am - 6p
SK-ACP Installation & Operating Manual READERS AND CARDS USING SK-ACP WITH SECURA KEY PROXIMITY READERS AND CARDS Secura Key offers proximity readers in a variety of sizes for use with the SK-ACP panel. Secura Key proximity readers read Secura Key cards only. Secura Key proximity cards have two encoded numbers: the ID Number which is different on each card, and the Facility Code (also called a system or site code) which is normally the same for all cards at a given site.
SK-ACP Installation & Operating Manual APPENDIX A WIRING AND SYSTEM CONFIGURATIONS SK-NETTM SOFTWARE SINGLE PANEL SYSTEM USING SK-NETTM SOFTWARE ¿ Pentium 200Mhz 2 CARD READER WITH ANY CARD TECHNOLOGY, WIEGAND OUTPUT, UP TO 40 BITS RS-232 NET-CONV-P OR ¿ SK-NETTM SOFTWARE RS-485 SK-ACP 1 ¿ MULTI-PANEL SYSTEM USING SK-NETTM SOFTWARE- SINGLE LOCATION Pentium 200 Mhz NET-CONV-P RS232-RS485 CONVERTER STAR / FANOUT “T” CONFIG SK-ACP DAISY CHAIN / MULTIDROP ¿ 1 SK-ACP SK-ACP 1 SK-ACP ¿ SK-
SK-ACP Installation & Operating Manual MULTI LOCATION SYSTEM WITH SK-NET-MLD SOFTWARE SK-ACP MODEM MODEM ¿ ¿ SK-ACP 2 TELCO LINE NET-CONV-P ¿ 1 SK-ACP SK-MDM SK-NETTM SOFTWARE ¿ SK-ACP 1 SK-ACP A virtually unlimited number of remote locations can be set-up on one PC with SK-Net-MLD Software.
SK-ACP Installation & Operating Manual APPENDIX B SK-NET EQUIPMENT COMPONENTS & SPECIFICATIONS TM SK-ACP: Two Door Access Control Unit RK-WM: or RK-WS or RK-WL Proximity Reader (2 per SK-ACP) RKCM-02 Molded Proximity Cards Specify Quantity or RKKT-02 Key Tags or RKCI-02 ISO Image-able cards ACCESSORIES NET-CONV-P — RS-232 to RS-485 Converter with Power Supply - one required per system (unless using a gateway connection) CBLSA — Demo Cable & Connectors For Bench Testing or field connection with a lapt
SK-ACP Installation & Operating Manual SPECIFICATIONS SK-ACP-LE PHYSICAL Depth Width Height Weight POWER REQUIREMENTS Power Supply Sold Separately 3.0” (7.62 cm) 10.0” (25.40 cm) 11.0” (27.94 cm) 68.8 oz (1.95 kg) Housing Material is All Steel; Color is Beige 16.5-24 VAC, 20 VA or 16-30 VDC, 100 mA plus reader current draw * A 12 VDC Power Supply may be used if connected to Battery Back-Up Leads. BACK-UP BATTERY 12 V, 1.
SK-ACP Installation & Operating Manual APPENDIX C CONNECTING A MODEM TO SK-ACP Using the SK-MDM Modem with the Secura Key 28SA-Plus Access Control Unit and/or SK-ACP Advanced Control Panel The SK-MDM Modem (Best Data Smart One 56SPX) has been selected by Secura Key for use with 28SAPlus Access Control Unit and the SK-ACP at remote locations. The SK-MDM is connected directly to the RS232 port of a 28SA-Plus or an SK-ACP.
SK-ACP Installation & Operating Manual NOTE: The default baud rate is 9600 baud. A 38,400 baud rate is recommended. You can change the baud rate of a 28SA-Plus using the PD-26 program deck, and the SK-ACP using SK-NETTM or a terminal program.
SK-ACP Installation & Operating Manual APPENDIX D CONNECTING AN SK-ACP OR 28SA-PLUS TO A LOCAL AREA NETWORK Using the SK-LAN External Device Server with the Secura Key SK-ACP and/or 28SA-PLUS. The SK-LAN External Device Server (Lantronix UDS-10-01) has been selected by Secura Key for use with our networkable access control system to permit connection over a 10BASE-T Local Area Network. The SK-LAN is connected directly to the RS-232 port of the gateway panel or reader.
SK-ACP Installation & Operating Manual DO NOT: • • • Plug the Ethernet cable into a telephone jack. Substitute another power supply. Mount the unit in a wet location or a location where temperatures may exceed 120 degrees F. Test the unit. 1. Ping. Go to “Start” / “Run”. Type “command”.Click OK. (This brings up a command prompt.) Type “ping . Press “Enter”. If the reply indicates “Request Timeouts” there is an error in the setup or connections.
SK-ACP Installation & Operating Manual D-3
SK-ACP Installation & Operating Manual APPENDIX E SK-ACP OR 28SA-PLUS TROUBLE SHOOTING GUIDE 1.0 Erratic or No Communication Between Readers and PC One of the most common problems with on-line systems is communications between reader stations and the PC. There are two different configurations for connecting the PC to the network, through the RS-232 Gateway, or with a Converter.
SK-ACP 2.2 Installation & Operating Manual Setup Location Properties 1. Select SK-NET™’s Explorer (Globe Icon). 2. Right click on the location name, and select Properties from the pull down menu. Click on the “Connection” tab. a) Uncheck “Gateway (RS232)”. Baud rate should automatically change to 38,400. b) In the box labeled “Connect Using” select the PC serial COM port to which the converter is connected. c) Be sure the “Local Connect” box is checked. d) Click on “Connect”. 2.3 Voltage Measurements 1.
SK-ACP Installation & Operating Manual 3.0 System Using A Reader Gateway (PC to Unit RS232 port) 3.1 Recommended Wiring 1. Cable Type: Belden 6304FE, or equivalent (5 conductor shield, not twisted). 2. If you are using the a 28SA-Plus unit, the SK-NM 485 module must be installed into the reader. This is not necessary for the SK-ACP. 3. DB9 Connector: verify wiring using a DB9 connector to the terminal block of the reader per figure 3. 4.
SK-ACP Installation & Operating Manual b) Pin 3 (Clear to Send, CTS). The voltage should read between +5 VDC to +12 VDC. This voltage comes from the PC. If the voltage is wrong or missing, disconnect the reader from the PC, and measure the voltages at the reader (should be 0.0 VDC) and at the PC (should be between +5 VDC to +12 VDC). c) Pin 4 (Request to Send, RTS). The voltage should read between -5 VDC to -12 VDC. This voltage comes from the Card Reader.
SK-ACP Installation & Operating Manual Windows® 95/98 Hyper Terminal Setup In order to connect to a ENTRACOMP® 28SA-Plus OR SK-ACP access control unit using only Windows, follow these steps: 1. Click on the start button on the lower left corner of the screen. 2. Select Programs. 3. Select Accessories. 4. Select Hyper Terminal. 5. Double click on Hypertrm. 6. Type Secura Key in the name field. 7. Click OK. 8. The next window will have a selection at the bottom of “Connect Using”.
SK-ACP Installation & Operating Manual System Architecture: MULTI-READER SYSTEMS: • Network is twisted-pair, shielded cable • Total system cable length, 4000 feet (1219.
SK-ACP Installation & Operating Manual APPENDIX F PREVENTING LIGHTNING DAMAGE SURGE PROTECTION FOR ACCESS CONTROL SYSTEMS Access Control equipment is susceptible to damage from lightning, especially when installed outdoors. Voltage spikes which travel through buried data cables, telephone lines or AC power lines can damage Access Control equipment indoors, as well.
SK-ACP Installation & Operating Manual Grounding the Surge Protector Surge protectors must be connected to a verified good, nearby earth ground. This can be AC Power Ground, a 10' Copper Ground Stake, or Building Ground. Run 16 AWG or heavier wire as short a distance as possible, and avoid any bends in the wire. Self-grounding Surge Protectors Do not use surge protectors unless they are equipped with a separate ground wire or ground screw.
SK-ACP Installation & Operating Manual F-3
SK-ACP Installation & Operating Manual WARRANTY (U.S. and Canadian) “This product is warranted against defects in materials and workmanship for a period of 2 years from the date of purchase. Secura Key shall, at its option, either replace or repair this product, if returned to us freight prepaid within the warranty period. This warranty does not include freight, taxes, duties, or installation expenses.
20447 Nordhoff Street • Chatsworth, CA 91311 Phone: 818-882-0020 • Fax: 818-882-7052 TOLL FREE: 800-891-0020 E-mail: mail@securakey.com • Web site: www.securakey.