User Manual
Page 9 American Access Systems / Security Brands, Inc.
PROGRAMMING
A person desiring access to the program mode will enter the present MASTER CODE. If the master code is valid
the yellow LED will come on and the individual will be prompted with a QUICKBEEP to enter a 3 digit number
corresponding to a SUBMODE. There are 4 groups of SUBMODES. Group 100 is for PROGRAMMING CODES, group 200
is for DELETING CODES, group 300 is MISCELLANEOUS SETTINGS and GROUP 400 is PRINT FUNCTIONS. There are a total
of 26 different submodes to choose from. They are as follows:
GROUP 100 SUBMODES (PROGRAMMING CODES)
SUBMODE DESCRIPTION
100 Program Access Codes
101 Program Managers Codes (15 Max 100 & 500: 30 Max 1000 &2000)
102 Change System Master Code
103 Program Sleep Code
104 Program Latch Code Relay A
105 Program Latch Code Relay B
106 Program Relay B Codes (5 Max 100 & 500: 10 Max 1000 & 2000)
GROUP 400 SUBMODES (PRINT FUNCTIONS)
SUBMODE DESCRIPTION
400 Print Audit Trail (Entire Contents of History Buffer)
401 Print Out All Current Access Codes
402 Print Audit Trail on Specic Code
403 Set Printer Baud Rate
404 Red Printing on Invalid Codes (For AAS idp562 Citizen Printer Only)
405 Print Out Current Unit Conguration (Prints out Status of 3 Strikes, Split
Relay, APB, Current Baud Rate, All Manager’s and Second Relay
Codes)
406 Print out last 100 Transactions
499 Clear Entire History Buffer
GROUP 200 SUBMODES (DELETING CODES)
SUBMODE DESCRIPTION
200 Delete Codes
299 Clear Memory
GROUP 300 SUBMODES (MISCELLANEOUS)
SUBMODE DESCRIPTION
300 Set Relay A Output Time (1/2 to 99 seconds)
301 Set Relay B Output Time (1/2 to 99 seconds)
302 Set Clock Time (Military Format)
303 Set Clock Date
304 Erase Memory and Fill with Random Codes
305 Generate Specic Number of Random Codes
306 Toggle 3 Strikes On/Off
307 Toggle Split Relay On/Off
308 Toggle AntiPassBack On/Off
309 Quiet Mode