User/Installation Manual ADVANTAGE DKE MODEL 26-100SG “Your Partner in Access Control” www.americanaccess.
AAS 2Year Limited Warranty What item(s) this warranty applies to: American Access Systems “Advantage DKE” access controls. What is covered: Any defect in materials or workmanship. For how long: Two years from date of purchase. What we will do: If your AAS product is defective and returned within 2 years of the date of purchase, we will repair it or, at our option, replace it at no charge to you. If we repair your AAS product, we may use new or reconditioned parts.
PARTS CHECKLIST Enclosed with this box you should have the following items. Qty Description 1 Control Station 2 Security Screws 1 Installation Instructions If any of the above items are missing from this box, contact American Access Systems Tools Needed For Basic Installation •• •• •• •• •• Wire nuts or appropriate connectors Wire strippers Wire cutters Standard 2 x 4 electrical box Digital or Analog multi-meter Technical/Customer Support 1-303-799-9757 or techsupport@securitybrandsinc.
STEP 1-MOUNTING THE UNIT Page 3 tells you what tools and instruments you will need to install your unit and presents a parts check list. Make sure to have all the tools listed. Upon opening the box, check off the items enclosed with the unit. If any items are missing from your unit, contact American Access Systems immediately. The ADV-100sg is designed to mount in a standard 2 x 4 electrical box. Two security screws are provided to prevent tampering.
THE MASTER CODE AND ACCESS CODES Your unit may be programmed with 100 multiple (4 digit) ACCESS CODES . The MASTER CODE is a 4 digit programmable code used for accessing the program mode. Note: The 1251 master code will not activate the relay and open the access device. SETTING OR RESETTING THE MASTER CODE To set or reset the master code back to the factory default of 1 2 5 1 should you ever loose or forget you master code. To do this follow these steps: (SEE PAGE 7 FOR LOCATION DIAGRAM) (1).
“2” Sub-Mode 2 (Delete Access Codes) To delete any access code from memory enter the MASTER CODE, followed by 2, and then each access code to be deleted (MASTER CODE) + 2 + (CODE TO BE DELETED) + (NEXT CODE TO BE DELETED) etc... (# to Exit) Should you make an entry error, simply press the * key and re-enter the correct data. You may continue deleting access codes in a successive manner. The unit will respond with a GOODBEEP with the successful deletion of each access code.
“4” Sub-Mode 4 (Set Relay Output Time from 1/2 to 9 seconds) To set the relay output time in seconds enter the PRESENT MASTER CODE, followed by 4, and then the relay output time in seconds. NOTE: “0” = 1/2 seconds. (PRESENT MASTER CODE) + 4 + (RELAY OUTPUT TIME) Should you make an entry error, simply press the * key and re-enter the correct data. You may enter any single digit value corresponding from 1/2 to 9 seconds of total length output time.
30 - 023 Board Layout Reset Button Processor Power Harness Relay Page 8 American Access Systems / Security Brands, Inc.
MASTER CODE ____________ Page 9 American Access Systems / Security Brands, Inc.
Customer Service and Tech Support Customer Service: 303-799-9757 Customer service is available free of charge. Hours are 8:00 a.m. to 4:30 p.m. MST. If you call, please have your Model and Serial Number to help our Technicians assist you. E-Mail: customerservice@securitybrandsinc.com Technical Support: 303-799-9757 Technical support is available free of charge. Hours are 8:00 a.m. to 4:30 p.m. MST. If you call, please have your Model and Serial Number to help our Technicians assist you.
Notes Page 11 American Access Systems / Security Brands, Inc.
“Your partner in access control” www.securitybrandsinc.