User Manual

22
Arnav Systems Inc.:
• R50, R50i, STAR 5000, FMS 5000, MFD (Multi-Functional Display).
II Morrow:
• FLYBUDDY, 2001 NMS
Trimble Nav Inc.:
NAV 1000, NAV 2000, TNL 2100, and TNL3100. The following Trimble systems
all require a RS-422 to RS-232 adapter: NAV 3000, TNL 1000, TNL 2000, TNL
2000A, TNL 3000, 2000 APPROACH, 2000 APPROACH PLUS, 2101
APPROACH, 2101 APPROACH
PLUS, 2101 I/O APPROACH, 2101 I/O APPROACH PLUS.
ENVIRONMENTAL TEST SPECIFICATIONS:
RTCA DO-204; DO-183
TSO-C126/C91a, RTCA DO-160E ENV. CAT.: F1XBA (204/183)
(204/183)XR(204/183)XXSXXXXAC(204/183)BXXXX (204)
TEMP. AND ALTITUDE: Category F1
Low Temperature: -20°C Operating; -55°C Storage.
High Temperature: +55°C Operating; +85°C Storage.
OPERATING LIFE: 5W @ 406.208 MHz for 24 hrs @ 20°C
50mW @ 121.5 MHz
50mW @ 243.0 MHz
(Minimum Requirement throughout a 50
hour period at 20°C)
TEMP VARIATION: Category B, 10°C minimum per minute
HUMIDITY: Category A, 95% RH, 50 hours
operating
SHOCK: 500G, 4 ± 1msec
IMPACT: Penetration of 55 lbs mass, 6 drops, 4
surfaces
CRUSH: 1000 lbs, 4 surfaces
VIBRATION: 10G, Sinusoidal, (5-2000) Hz, 3 axes
WATERPROOF: Category R, 15 minutes Spray, 6 sides
IMMERSION SALT WATER: Category S, 24 hours Immersion, 160
hours at + 55°C
SALT SPRAY: Category S, 48 hours exposure to the
Salt Fog, and 48 hours drying