Owner`s manual

SYSTEM INSTALLATION AND SERVICE
AT AND 3T STEAMERS
4211-103 10-10-11
Page 9
STEAM ROOM WALL
SENSOR CABLE
7/8” HOLE
SILICONE CAULK
TEMPERATURE
SENSOR
PROBE
MUST BE POINTED DOWN
TO 2nd SLAVE GENERATOR
MASTER GENERATOR
Make sure that the sensor probe is pointing down once installed. Tape the sensor in
Place while the silicone hardens. Route the generator end of the sensor cable through
the generator hole marked CONTROL WIRING ENTRY using the control cable strain
relief. Plug the sensor cable into the RM TEMP connector on the printed circuit board
assembly. See diagram 12.
6. WIRING THE GENERATOR CONTROL CABLES
Choose one generator to be your “Master” unit. This generator will control the other one
or two “slave” generators in the system. If the generators are not the same size (kW),
the largest wattage generator should be the master.
At the Master generator: Route the generator end of the control cable through the
generator hole marked CONTROL WIRING ENTRY using the strain relief provided.
Plug the control cable into the T100 metal shielded connector on the printed circuit board assembly. See diagram 12.
Connect a shielded control cable to the Master generator’s OUT1 jack and route this cable out the Master’s CONTROL WIRING ENTRY and into the rst slave
generator though its CONTROL WIRING ENTRY hole. Connect this cable to the slave’s T100 jack. If a second slave generator is to be used, route another control
cable in the same manner from the Master’s OUT2 jack to the slave’s T100 jack. Note: If additional room is needed at the Master generator for routing the slave
cables, a knock out is provided next to the CONTROL WIRING hole. Secure all cables.
SECTION 5: WIRING INSTRUCTIONS (contrinued)
SLAVE GENERATOR
DIAGRAM 12: CABLING THE GENERATORS
DIAGRAM 13: TEMPERATURE SENSOR INSTALLATION
SECTION 6: ELECTRICAL INFORMATION CHART
MODEL
AC
VOLTAGE PHASE
NOMINAL WATTAGE NOMINAL AMPERAGE
UL RECOMMENDED
PROTECTIVE DEVICE
@208V @240V @208V @240V @208V @240V
AT5 208/240V 1 3,750 5,000 18.0 21.0 25 30
AT7 208/240V 1 5,250 7,000 25.3 29.0 35 40
AT10 208/240V 1 7,500 10,000 36.1 41.5 50 60
AT12 208/240V 1** 9,000 12,000 28.8/14.4 33.3/16.7 40/20 50/25
AT14 208/240V 1** 10,500 14,000 32.5/18.0 37.5/20.8 50/25 50/30
3T8 208V 3 7,900 - 21.9 - 30 -
3T10 208V 3 10,100 - 28.1 - 35 -
3T12 208V 3 33,300 - 31.3 - 40 -
3T14 208V 3 14,500 - 40.2 - 50 -
* 208 VAC wired units must be supplied with a minimum of 195 VAC while operating (heating).
Unit is rated for copper wire only. All wire is UL approved 300V 75°C minimum unless otherwise speci ed.
** Single phase 12kW & 14kW require two separate line feed circuits.