Syntax:
priority-temp <0-3>
<0-255>
Parameter :
<0-3>: Port priority
<0-255>: The temperature at which the ports with the corresponding
priority will be turned off
EXAMPLE:
show: ThecommandletsyouShowthermalprotection
information
Syntax:
show <cr>
Parameter :
<cr> means it without any parameter needs to type.
EXAMPLE:
Switch(thermal)# show
Priority Temperature
-------- -----------
0 255 C
1 255 C
2 255 C
3 255 C
Port Priority Chip Temperature Port status
---- -------- ---------------- ---------------------------------------------
1 0 59 C Port link operating normally
2 0 59 C Port link operating normally
3 0 59 C Port link operating normally
4 0 59 C Port link operating normally
Switch(thermal)# priority-temp 1 99
Switch(thermal)# show
Priority Temperature
-------- -----------
0 255 C
1 99 C
2 255 C
3 255 C
Port Priority Chip Temperature Port status
---- -------- ---------------- ---------------------------------------------
1 3 59 C Port link operating normally
2 0 59 C Port link operating normally
3 0 59 C Port link operating normally