System information
Publication date: Feb., 2012
Revision A1
- 168 -
CLIReferenceGuide
Copyright @ 2012 by Amer Networks
Chapter 38 SFlowCommandsofCLI
SFlow
The sFlow Collector configuration for the switch can be monitored and
modified here. Up to 1 Collector is supported. This page allows for
configuring sFlow collector IP type, sFlow collector IP Address,Port
Number,foreachsFlowCollector
Table 37: SFlow Commands
Command
Function
collector
sFlow Collector Configuration
sampler
sFlow sampler Configuration
show
Show sFlow
collector: The command lets you set sFlow Collector
Configuration
Syntax:
collector IPv4/ IPv6 <ip-address> <1-65535> <0-2147483647>
<200-1500>
Parameter :
IPv4: IP type
IPv6: IP type
<ip-address>: IP address
<1-65535>: TCP/UDP port number. By default, the port number is
6343
<0-2147483647>: Set the receiver timeout for list of receiver ID
(RID). Collector cannot collect samples unless receivertimeout
<200-1500>: Set the reciever datagram length for list of receiver ID
(RID)
EXAMPLE:
Switch(sflow)# collector ipv4 192.168.100.100 6345 99 1500
Switch(sflow)# show
% Incomplete command
Switch(sflow)# show collector
Configured Current
---------------- ----------------
Collector Id 1 1
IP Type IPv4 IPv4
IP Address 192.168.100.100 192.168.100.100
Port 6345 6345
Time Out 99 90 Timer is still alive!
Datagram Size 1500 1500