Specifications

LB6 Aux Master Comms Module
Jumper and Switch Options – GL 1868
P1
User Tally / On Air Select
To select the internal User Tally indicator, link pins1–3
(Factory Pre-set).
To select the external User Tally, link pins3–5.
Applying an active low to a pin on the 25 way D Type
connector controls the external User Tally.
This is located on the back panel.
To activate On Air Mode, link pins4–6(Factory Pre-set).
To disable it, link pins2–4.
P2
Slate Destination Select
To enable the oscillator to slate to the Stereo Bus, link pins
1 – 3 (Factory Pre-set).
To enable it to slate to the Group Buses, link pins2–4
(Factory Pre-set).
To disable slate to the Stereo Bus, link pins3–5.
To disable the slate to the Group Buses, link pins4–6.
P3
Comms Output / Comms to Monitor 2
To enable the comms signal to route to the Comms
output, link pins3–5(Factory Pre-set).
For the oscillator to route to the Comms output link pins
1–3.
To enable the comms signal to route to the Monitor 2
output, link pins4–6.
To disable the comms to Monitor 2, link pins2–4
(Factory Pre-set).
5-24 Modules Issue 3 © AMEK