Specifications
P10
Cleanfeed position 10
If position 10 has a Group module fitted P10 must be in
the disabled position.
If a Stereo module is fitted and it is to be used as a
Cleanfeed input P10 has to be enabled.
To enable link pins1–2.
Jumpers P11 and P12 are the Virtual Earth Disable options and will be set
depending on the operation and configuration of the console.
P11
Virtual Earth Disable options
Cleanfeed Jumpers. In an eight group console no jumpers are
fitted. In a four group console jumpers are fitted to disable
the unused Cleanfeed buses 3 and 4. To disable link pins5-6
and7-8.
If the Cleanfeed buses 3 and 4 are unused link pins1-2
and3-4.
When Group modules 5 to 8 are omitted the relevant virtual
earth buses are grounded. To disable the Groups 5 to 8 link
pins 9 – 10, 11 – 12, 13 – 14 and 15 – 16.
P12
When Group modules 5 to 8 are omitted the relevant virtual
earth buses are grounded. To disable the Groups 5 to 8 , link pins1-2,3-4,
5-6and7-8.
5-14 Modules Issue 3 © AMEK