User manual
44
to enable the function of Netcom module.
Baud rate You need to select a correct Baud rate if you want to control the Speed dome
camera or P/T/Z camera from DigiCap II DVR. (Default setting is 9600 bps)
If you want to change the baud rate, please change the hardware and software at the same time.
There is a Dipswitch on the back panel for the Baud rate setting, the description as below:
1. You must select 9600 baud rate, enable Checksum icon and select “ Peclo P “,
when you use I-View’s FastCam Speed dome camera series.
2. The ID 0 of Peclo “ P “ is same as Camera 1 of DigiCap II , ID 1 same as camera 2.
Select Modem For AnyView Pro user or using Phone/Pager notify function should select
which modem will be used and enable “Monitor” below to communicate with DVR. If
user’s modem and fax share one telephone line, user must disable ”monitor” when no more
connection required otherwise modem will occupy phone line always.
1. You can select “None” to leave modem open for other communication software or voice
calls.
2. You must select which modem will be used and enable “Monitor” for AnyView Pro user
and Phone/Pager notify functions.
3. Please contact to your local dealer for asking the model of Modem.
Screen rotation time regulates the time period of camera rotation by clicking on the
main screen. Click on the icon again to disable the rotation function. (Default setting is 5
seconds)
Baud rate
Pin
9600 4800 2400 1200
Pin 1 & Pin 2
Open Short Open Short
Pin 3 & Pin 4
Open Open Short Short