Installation Steps:
Step 1:
In the selected starting corner, place ½” spacers at each
side of the starting corner, lay the first AmDry Panel.
Cut an Amdry connector @ 22 1/2for the short end
(this will allow for the 3/8” connector insert in the long
side panel on either side.)
Place the 22 1/2” connector in the first laid panel, this
can be inserted easily by hand and a light tap with the
rubber mallet will ensure a tight connection. Place 2
more spacers at the side of the wall and slide the
second Amdry panel into the connector of the first
panel. Continue on with this process until you come to
the end of the wall. It may be necessary to cut the last
panel of each row to fit the room size. Remember to
include the ½” spacer at the end of each row. Place the
4’ Amdry connectors on the long side of the Amdry
panels that have been installed