Specifications
34 Product Errata
41322 Rev. 3.84 August 2011
Revision Guide for AMD Family 10h Processors
443 Instruction-Based Sampling May Not Indicate Store Operation No fix planned
459 DDR3-1333 Configurations with Three DIMMs per Channel
May Experience Unreliable Operation
X
486 Processor Thermal Data Sheet Specification Error X X
521 C1E Resume Failure With Certain Registered DIMM
Configurations
X
550 Latency Performance Counters Are Not Accurate X X X
610 Processor with Message-Triggered C1E Enabled May Report a
False L3 LRU or Tag Machine Check
X
625 SB-RMI Writes May Not Be Observed by Processor X
643 Processor May Increment CPU Watchdog Timer at an Incorrect
Rate
No fix planned
669 Local Vector Table Interrupt May Cause C1E Entry Without
Caches Flushed
X
670 Segment Load May Cause System Hang or Faul
t After State
Change
No fix planned
Table 27. Cross-Reference of Product Revision to Errata (Continued)
No. Errata Description
Revision Number
DR-BA
DR-B2
DR-B3
RB-C2
BL-C2
DA-C2
RB-C3
BL-C3
DA-C3
HY-D0
HY-D1