User`s guide
Chapter 2 Configuring Hardware Elements 33
Example: Display Hardware Status for an Oracle
Fabric Interconnect F1-15
The show hardware command displays comprehensive output of all the important
hardware information for a Oracle Fabric Interconnect. This example is for a F1-15
with an SDR fabric.
show hardware
# Model: F1-15-CH-DDR
# Serial: 410510043
# Base MAC: 00:13:97:01:20:00
# Base WWN: 50:01:39:70:00:00:20:00
# Locator LED: off
#
# Date: Wed Jan 25 16:13:38 PST 2012
# User: admin
#
#
## IO Card Version status ########################################
slot type model part-num serial
vchip-ver xt-ver primary-boot-ver secondary-boot-ver diag-ver
-----------------------------------------------------------------------------
4 nwEthernet4Port10GbCardEthIb VPE-MOD-10GE-4P 705-00094-01.01.09 321111829
N/A 1.0.36843[IB] 4.00.19 4.00.17 4.19
5 nwEthernet1Port10GbCard VP-MOD-10GE-1P 705-00018-03.02.06 500812687
N/A 1.0.35348 4.00.19 4.00.07 4.19
6 sanFc2Port4GbCard VP-MOD-FC-2P 705-00015-02.02.05 500812736
1.0.29167 1.0.34543 4.00.19 4.00.07 4.19
8 nwEthernet10Port1GbCardEthIb VPE-MOD-1GE-10P 705-00070-03.01.02 521019122
N/A 1.0.35787[IB] 4.00.19 4.00.16 4.19
9 sanFc2Port8GbLrCardEthIb VP-MOD-8FC-2P 705-00074-01.01.03 031119288
4.0.35913 1.0.35787 4.00.19 4.00.07 4.19
10 sanFc2Port4GbCard VP-MOD-FC-2P 705-00015-01.01.07 080610376
1.0.29167 1.0.34543 4.00.19 4.00.07 4.19
12 sanFc2Port4GbLrCardEthIb VPE-MOD-4FC-2P 705-00072-02.01.03 061119840
3.0.34198 1.0.35787 4.00.19 4.00.07 4.19
14 nwEthernet10Port1GbCard VP-MOD-1GE-10P 705-00025-03.02.06 400812310
N/A 1.0.35348 4.00.19 4.00.07 4.19
15 nwEthernet1Port10GbCard VP-MOD-10GE-1P 705-00018-01.01.00 490610749
N/A 1.0.35348 4.00.19 4.00.07 4.19
9 records displayed
## IO Card Environment status ####################################
slot type state temperatures voltages