User`s guide

390 XgOS User’s Guide September 2014
When you issue the system upgrade command, the Fabric Interconnect begins the
upgrade. While the upgrade occurs, status messages are displayed, as shown in the
following example:
At this point, the Fabric Interconnect will restart, and you will be logged out. Wait
for a few minutes so that the Fabric Interconnect can complete its reboot, then log in.
When the Fabric Interconnect is rebooting, reboot ESX Server 1.
The Fabric Interconnect will take approximately 2 minutes to reboot, but
approximately 10 minutes for I/O cards, virtual resources, and all related services to
come back up and restore service.
14. Log in to Fabric Interconnect 1.
15. Wait for the I/O cards in the Fabric Interconnect to finish initializing before
proceeding.
To determine whether the I/O cards are initialized, use the show iocard
command. The Fabric Interconnect displays the state of all cards. When the state
of the cards is up/up, you are ready to proceed.
Copying...############################################################# [100%]
You have begun to upgrade the system software. Please be aware that this will
cause an I/O service interruption and the system may be rebooted.
The following software will be installed
1. XgOS Operating System software including SCP Base OS
2. XgOS Front-panel software
3. XgOS Common Chassis Management software on IOC
4. XgOS VNIC Manager and Agent software
5. XgOS VN10G and VN10x1G Manager and Agent software
6. XgOS VHBA and VHBA-2 Manager and Agent software
7. XgOS VN10G and VN10x1G Manager and Agent software with Eth/IB Interfaces
8. XgOS VHBA-3 Manager and Agent software
9. XgOS VHBA 2x 8G FC Manager and Agent software
10. HCA's Firmware and Option ROM
Are you sure you want to update the software (y/n)?y
Running verify scripts...
Running preunpack scripts...
Installing... ################################################# [100%]
Verifying... ################################################# [100%]
Running preinstall scripts...
The installer has determined that a cold restart of the Director is necessary
Installing package...
Running postinstall scripts...
slot state descr type v-resources
-----------------------------------------------------------------
4 up/up nwEthernet10Port1GbCard 0