User`s guide

Chapter 20 Upgrading XgOS 377
ConnectX and ConnectX-2: 2.7.0 and later
It requires option ROM 2.8.7 to support SAN boot. If your firmware and XgBoot
versions are as shown above, you can skip Step 2.
2. On your Linux host server, upgrade the HCA firmware and the option ROM if
necessary.
a. If you haven’t already done so, log in as root to the host server.
b. Upgrade the Xsigo HCA firmware package on the server.
Note Replace xsigo-hca-firmware_2.8.7.i386.rpm with the Xsigo host
driver for your server. Supported host drivers for each operating system are listed in
the release notes.
c. Run xg_config to upgrade the firmware and option ROM.
d. If you are using SAN boot or might decide to in the future, select option 2.
Otherwise, select option 1.
In the following screen output example, option 2 was selected:
rpm -Uvh <xsigo-hca-firmware_2.8.7.i386.rpm>
/opt/xsigo/bin/xg_config
#############################################################
# Main Menu
#############################################################
Selected card:
Node GUID : '0002:c902:0020:4934'
Board ID : 'MT_0150000001'
CA type : 'MT25208'
Firmware version : '5.3.0'
Hardware version : 'a0'
Option ROM version : 'XgBoot Version 2.8.7'
1) Flash HCA Firmware
2) Flash HCA Firmware + Option ROM
3) Flash Option ROM
4) Change selected card
0) Quit
Select option>
#################################################################
# Flash HCA Firmware + Option ROM Menu
#################################################################
Selected card:
Node GUID : '0002:c902:0020:4934'