User`s guide

Chapter 20 Upgrading XgOS 375
5. Wait for the I/O cards in the Fabric Interconnect to finish initializing before
proceeding.
To determine whether the I/O cards are initialized, use the show iocard
command. The Fabric Interconnect displays the state of all cards. When the state
of the cards is up/up, you are ready to proceed.
6. When the I/O cards all show up/up, check the state of the vNICs and vHBAs:
The state of the vNICs and vHBAs should be up/up.
7. When all vNICs and vHBAs in the Fabric Interconnect have come to up/up
state, log in to the host server.
8. On the host server, verify that all the vNICs and vHBAs have reconnected and
returned to up/up state.
For example, on an ESX Server:
When the State field shows active, the vHBA is up and connected.
9. When the Fabric Interconnect has completed its restart, verify that the new
software has been installed:
show vnic *
show vhba *
esxcfg-mpath -l
fc.5001397100002505:5001397000002505-
fc.2001000b08002539:2400000b08043110-eui.00
0b080074002539
Runtime Name: p3:C0:T0:L2
Device: eui.000b080074002539
Device Display Name:Pillar Fibre Channel Disk
(eui.000b080074002539)
Adapter: p3 Channel: 0 Target: 0 LUN: 2
Adapter Identifier: fc.5001397100002505:5001397000002505
Target Identifier: fc.2001000b08002539:2400000b08043110
Plugin: NMP
State: active
:
:
show system version
Build 3.6.0-XGOS - (root) Thu Jul 21 23:39:53 UTC 2011