User`s guide
Chapter 8 Virtual Host Bus Adapters (vHBAs) 157
ā¼ Configure a Port for Direct-Attached Storage
The Oracle Fabric Interconnect supports direct-attached storage. To configure a port
for such storage:
1. Set the desired port type.
For example, to configure port 1 on I/O module 3 as an ālā port:
2. Reset the I/O card to make your change take effect.
For example:
You can configure each port on a card differently. Issue the reset command after
making all port configuration changes.
If you are reconfiguring a port, remove all but one vHBA from that port. Then
follow the steps above to configure the port for direct-attached storage.
Note ā When you configure a LUN on this direct-attached device, you will see the
WWPN of the port, not of the vHBA.
type sanFcPort
state up/up
descr
wwnn 50:01:39:71:00:00:B0:1F
wwpn 50:01:39:70:00:00:B0:1F
rate auto/4Gbps
frame-size 2048/2048
exec-throttle 65535
int-delay 1000
fc-link-down-timeout 10
login-retry 8
login-timeout 4
fc-target-port-down-timeout 60
topo F
loop-delay 5
tape-support true
vhbas 4
-----------------------------------------------------------------
1 record displayed
set fc-port 3/1 -topology=l-port
set fc-card 3 reset