User`s guide

Chapter 8 Virtual Host Bus Adapters (vHBAs) 155
Parameter Description
-descr=<text> Applies a text description to the FC port.
Quotes are required around multiple words
containing spaces in between.
-detail Enables you to display detailed information
about the Fibre Channel port configuration,
properties, and state. Some Fibre Channel port
parameters are displayed only through this
option.
-fc-link-down-timeout={<number>|default} When a fibre link goes down, the FC port will
wait (delay) the specified number of seconds
before declaring the fibre link down. This
parameter value in seconds that determines the
duration for which a link can experience a loss
of signal, or be non-operational before the
firmware declares the link is down and sends a
link down event. This parameter guards against
link flapping and excessive reporting of link-
state changes whenever there is a constant
change in the state of the link. Specify a number
of seconds between 0 and 60, or do not specify
any millisecond value to use the default time-
out. The default is 30 seconds.
-fc-target-port-down-timeout={<number>|default} When a Fibre Channel port goes down on a
target, the Oracle Fabric Interconnect will wait
(delay) the specified of seconds before declaring
the port down. This parameter is a counter that
determines the maximum number of seconds a
port can remain offline. If the specified number
of seconds is exceeded, the port is timed out
and declared down. Specify the time-out value
as a number of seconds between 0 and 60, or do
not specify any number to use the default retry
limit. The default limit is 30 seconds.