User`s guide

102 XgOS User’s Guide September 2014
1. Set the input vNIC to mirror to an output vNIC:
2. Set the direction of traffic that will be mirrored:
3. Display detailed vNIC information to verify that the mirror was created.
Look for the mirror field at the bottom of the display.
As an option, you can also display the following commands to determine that
mirror ports and mirror vNICs are configured and passing traffic:
If the counters are incrementing on the mirror port or vNIC(s), then the mirror is
configured and supporting traffic.
set vnic vn1.pubstest -mirror=vn6.pubstest
set vnic vn1.pubstest -mirror-direction=both
show vnic vn1.pubstest -detail
-----------------------------------------------------------------
name vn1.pubstest1
state up/up
mac-addr 00:13:97:01:80:19
admin-ipaddr 0.0.0.0/32
oper-ipaddr 0.0.0.0/32
descr
if 4/1
if-state up
mcast-group
type dhcp
mtu 1500
group
group-pref
ha-state
flags ---
vlans none
access-vlan 1
mode access
queue-map-type disabled
qos i-
local-id 0
mirror vn6.pubstest(both)
-----------------------------------------------------------------
1 record displayed
watch ioports
watch vnics