Specifications
E PENTIUM® PRO PROCESSOR AT 150, 166, 180, and 200 MHz
63
0.085”
0.130”
Height
0.150”
2.235”
Figure 41. Analysis Heat Sink Dimensions
Table 25 shows the T
A
required given a 29.2 W processor (150 MHz, 256K cache), and a T
C
of 85°C.. Table 26
shows the T
A
required assuming a 40W processor. Table 25 and Table 26 were produced by using the
relationships of Section 6.1.3. and the data of Table 24.
Table 25. Ambient Temperature Required per Heat Sink Height for 29.2 W and 85°° Case
T
A
vs. Airflow [Linear Feet per Minute] and Heat Sink Height
1
Airflow (LFM): 100 200 400 600 800 1000
With 0.5” Heat Sink
2
—-825364347
With 1.0” Heat Sink
2
10 36 53 57 61 62
With 1.5” Heat Sink
2
36 46 58 62 64 65
With 2.0” Heat Sink
2
42 49 59 63 64 66
NOTES:
1. At sea level. See Table 24.
2. Heat Sink design as in Table 24.