Instruction manual

22
TROUBLE SHOOTING
Never try to repair or dismantle the unit yourself.
Before calling for assistance please check the points below.
The unit doesn’t run. Is the machine plugged in?
Is the mains power supply on?
Is the water full indicator on? (If so, the water tank is full or it isn’t positioned properly).
The unit seems to extract little water.
Are too many windows or doors open?
Is there something in the room producing lots of heat?
Is the room cold – the colder the air the less moisture the unit will extract.
Is the dust filter dirty?
Is the room humidity already quite low?
The unit seems to do nothing. Is the dust filter dirty?
Is the air intake or outlet blocked?
Is the room humidity already quite low?
Is the room temperature below 5 °C? The fan may run without the compressor.
Too noisy.
Is the machine positioned unevenly so as to create vibration?
Is the floor underneath the unit uneven or loose fitting?
Is there any foreign body interfering with the unit?
The unit’s fan doesn’t seem to be
revolving.
Is the filter blocked up?
Is there any foreign body interfering with the unit?
The continuous drainage is not working. Does the hose have a downward slope throughout its length from the dehumidifier?
Is there a kink or sharp bend in the hose?
ENGLISH
TECHNICAL DATA
Due to our continuous R+D programme, specifications may change without prior notice.
For current specifications please refer to the rating label on your machine.
Model No.
DC 10 DC 14
Electricity
220-240 V/ 50 Hz
Working temperature
5 til 35 °C
Refrigerant
R-134A
Refrigerant load
200 200
Moisture removal Litres/day (32 °C, RH 90%)
10 14
Power consumption Watt (32 °C, RH 90%)
253 273
Net weight kg
15 16
Dimensions cm (WxDxH)
32,5 x 35,5 x 54,0