Dehumidifier – D 850E - Instruction manual version 02
Content 1. Description of dehumidifier 1.1 . General data 1.2 . Technical data 2. Operation and usage 2.1 . Usage 2.2 . Location and installation 2.3 . Preparing for starting 2.4 . Operation 2.5 . Breakdown 2.6. Maintenance 2.6.1. Cleaning the air filter 3. Trouble shooting, causes and its remedy 4. Warranty 4.1 . Warranty conditions 4.2 .
1. Description of device 1.1 . General data Dehumidifiers can be used wherever problems with high air humidity occur, i.e. not only in swimming pools, but also in rehabilitation or telecommunication centers, restaurants, hairdresser's saloons, laundries, kitchens, etc. or generally to reduce humidity in the air. The dehumidifiers are equipped with dust filters, enabling them not only to dehumidify but also to purify the air. 1.2.
Picture no. 1 description of dehumidifier and control panel 1. 4. 5. 6. 7. 8. 2. 3. 9. 10. 12. 1. 2. 3. 4. Outlet of air Intake of air Dust filters Control panel 2.2. 11. 5. Indication of low / high speed of fan 6. Indication of durability run 7. Required humidity 8. Run compressor indication 9. Display of measuring humidity 10. Switch 11. Regulator of humidity 12. Reverser of speeds of fan Location and installation The unit can be either located on the floor or hanged on the wall.
2.3. Preparation for starting and starting Dehumidifier has button SPEED placed on the control panel ( picture 1/12 ). It enables to choose speed of flowing air. (You can choose one of two speeds. ) Regulator of humidity – humidistat is another operating element. Humidity regulator provides switching off or switching on of compressor and it keeps the constant humidity of air. Humidistat is adjust by button HUMIDITY (picture 1/11 ). You choose required humidity of air by pressing button.
2.6. Maintenance Regular preventive service of the device (paid service) is necessary for recognition of warranty. It is necessary to have preventive service on your dehumidifier done every year starting one year after purchase. Customer is obliged to contact service and ask for term of preventive service (by phone or in writing form). 2.6.1. Cleaning the air filter Air circulation is impeded and the efficiency of the dehumidifying and air purifying functions decreases when the filter is dirty.
3.
4.Warranty 4.1. Warranty conditions Warranty 24 months is not relate to components with lower service life ( like dust filter, thermal safety-fuse ). If defect comes up in warranty and was not caused by both user and some disasters. It is not defect of element with lower service life, the unit will be repaired free of charge, providing that: - date of sale is not older than 24 months, - the unit was maintained according to point 2.6.
1. Drawing of D 850 E 2. 3. 780 700 1. Dry air discharge 2. Control panel 3.