Split Wall-Mounted Air Conditioner
Releasing procedure
When the indication on dispiay screen is 24 hour,press the TIMER button again to delete the timed mode.
SLEEP OPERATION
Use this mode to reduce operation sound when sleeping,etc.
Press the SLEEP button,the air fiow sound from the indoor unit is decreased.
Press the SLEEP button again can release the mode.
NOTE:
•  Use the sleep mode  when  you  are going  to bed.If this mode  is used in the  day,the capacity is reduced  since the 
ambient temperature is too high.(COOL MODE).
•  During  the  operation  of  cooling,the  room  temperature  will  be  raised  gradually  by  2°C(4''F)  higher  than  the  setting 
after the machine begins to operate in the sleeping mode.
•  During  the  operation  of  heating  mode,the  room  temperature  will  be  dropped  gradually  5°C(9'F)  lower  than  the 
setting after the machine begins to operate in the sleeping mode.
REPLACEMENT OF BATTERIES
•  When the signal  from the remote controller  becomes weak and the 
indoor unit  can not  receive it  properly;orthe indications  on  the display 
screen  becomes  blurred,please slide  the  back  cover and  replace  with 
two new batteries.
• The positive and negative poles must match the installation positions.
•  New batteries of the same type have to be used for replacement.
•  If  the remote  controller is not  to be  used for  long  time,take out  the 
batteries  so  as to  prevent  the  leakage  of  the  electrolyte  from  damaging 
the controller.
•  If when the remote contnjiler is at abnormal  state,you can take out 
the batteries on the back cover to clear off the display.
[Features of Heating Operations]
Basic principles and performances
Remote Controller 1
-C CLK button )
It does not work on this model.
—C RST button )
This button iet computer reset, 
(push the RST button with the tip of a 
ball pen,etc)
Unload the back Cover
Remote Controller 2
O  The  machines absorb  heat  from  the outdoor  air  and  transfer  it indoors  so as  to heat  the  room air.  The heating 
capabilities  through  this  principle  of  heat  pump  go  up/down  with  the  increase/decrease  of  the  temperatures  of  the 
outdoor air.
O It only needs a fairly short time for such hot air circulation system to raise the room temperature.
O  When  the outdoor  air  temperature  is very  low,  the  system can  be  used  together with  other heating  devices. But 
good ventilation should be maintained to ensure safety and prevent accidents.
When  the  outdoor  air  temperature  is very  low  and  humidity  is  very high,  frosting  will  occur to  the  heat  exchanger of 
the  outdoor  unit,  which  has  negative  impacts  upon  the  efficiency  of  the  heating  performance.  In  such  case,  the 
automatic  defrosting  function  will  come  into  play.  The  heating  operation  will  be  stopped  for  5-10  minutes  to  do  the 
defrosting.
O The fans of both the outdoor and indoor units are stopped.
O During  the  defrosting,  the  outdoor  unit  might  generate  some  steam.  It  is  caused  by  fast  defrosting,  which  is 
not a performance failure.
O Upon the completion of the defrosting process, the heating operation is resumed.