Block Transfer Write Format (continued)
Programming Bits
Z
-
Autozero, Bit 00
- When this bit is set, the module will zero the position of the transducer.
P
-
Program Parameters, Bit 01 -
When this bit is set, the module programs itself with the
state of bits 02 and 03. These parameters are the Count Direction and Transducer Type of
the transducer. Program Bit 1 will also act on the Number of Turns and Full Scale Count
parameters.
D
-
Count Direction, Bit 02 -
This bit is only acted on when the Program Parameter Bit (01) is
set. This bit programs the state of the Count Direction parameter. When this bit is reset, the
Count Direction is set to its Positive value. When this bit is set, the parameter is set to its
Negative value.
Y
-
Transducer Type, Bit 03 -
This bit is only acted on when the Program Parameter Bit (01)
is set. This bit programs the state of the Transducer Type parameter. When this bit is reset,
the Transducer Type bit is set to AMCI transducers. When this bit is set, the parameter is set
to Autotech transducers.