User manual
Chapter 2 Installation
12 ADVANCED MICRO CONTROLS INC.
Installing the Module
Remove system power before removing or installing any module in an I/O
chassis. Failure to observe this warning may result in damage to the mod-
ule's circuitry and/or undesired operation with possible injury to personnel.
Keying Bands
Plastic keying bands can be inserted into the top backplane connector to prevent the insertion
of other modules.
hý
Pins 28 and 30
hý
Pins 32 and 34.
Transducer Specifications
HTT-20, HTT-400, HTT425-F,
HTT425-T Transducers
HTT425 Motor Mount
Transducers
Shaft Diameter ........ 0.625" Shaft Diameter ........ 0.250" or 10mm
Shaft Loading .......... Radial: 400 lbs. max.
Axial: 200 lbs. max.
Shaft Loading .......... Radial: 40 lbs. max.
Axial: 20 lbs. max.
Starting Torque ....... 8 oz.in. @ 25° C Starting Torque ....... 1.5 oz.in. @ 25° C
Moment of Inertia ... 20 oz-in-sec
2
Moment of Inertia ... 4 oz-in-sec
2
Enclosure ................ HTT-20: NEMA 13
HTT400:NEMA 4
HTT425: NEMA 4X
Enclosure ................. NEMA 4
When properly installed
Environmental (All Transducers)
Operating Temp
-20 to 125°C
Shock
50G’s for 11 mSec
Vibration
5 to 2000 Hz @ 20 G’s
Table 2.2 Transducer Specifications
Transducer Mounting
All AMCI resolver based transducers are designed to operate in the industrial environment
and therefore require little attention. However, there are some general guidelines that should be
observed to ensure long life.
hýLimit transducer shaft loading to the following maximums:
Radial Load Axial Load
All 0.625" Shafts
100 lbs. (445 N) 50 lbs. (222.4 N)
All other Shafts
30 lbs. (133 N) 15 lbs. (66.7 N)
Table 2.3 Transducer Bearing Loads
hýMinimize shaft misalignment when direct coupling shafts. Even small misalignments
produce large loading effects on front bearings. It is recommended that you use a
flexible coupler whenever possible.