User guide
Table Of Contents
- Title Page
- Table of Contents
- About this User Guide
- Introducing the 3ware® SATA RAID Controller
- Getting Started with Your 3ware RAID Controller
- First-Time RAID Configuration Using 3BM
- Driver Installation
- Driver Installation Under Windows
- Driver Installation Under Linux
- Obtaining 3ware Linux Drivers
- Driver Installation Under Red Hat Linux or Fedora Core 5
- Materials required
- Creating a Red Hat Linux Driver Diskette
- Installing the 3ware Kernel Driver Module while Installing Red Hat Linux on a New Unit
- Installing the 3ware Kernel Driver Module on a Red Hat or Fedora Core Linux System that Boots From a Different Device
- About Variables In the Kernel Driver Module Installation Instructions
- Driver Installation Under SuSE Linux
- Compiling a 3ware Driver for Linux
- Driver Installation Under FreeBSD
- 3ware BIOS Manager 2 (3BM 2) Introduction
- 3DM 2 (3ware Disk Manager) Introduction
- Configuring Your Controller
- Configuring Units
- Configuring a New Unit
- Creating a Hot Spare
- Naming a Unit
- Setting Unit Policies
- Changing An Existing Configuration by Migrating
- Deleting a Unit
- Removing a Unit
- Moving a Unit from One Controller to Another
- Adding a Drive
- Removing a Drive
- Rescanning the Controller
- Maintaining Units
- Checking Unit and Drive Status through 3DM
- About Degraded Units
- About Inoperable Units
- Alarms, Errors, and Other Events
- Background Tasks
- Scheduling Background Tasks
- Locating a Drive by Blinking Its LED
- Maintaining Your Controller
- Determining the Current Version of Your 3ware Driver
- Updating the Firmware and Driver
- Downloading the Driver and Firmware
- Updating the Firmware Through 3DM 2
- Updating the 3ware Driver and Firmware Under Windows
- Using the Update Utility With Multiple Controllers
- Updating the 3ware Driver Under Windows XP
- Updating the 3ware Driver Under Red Hat or Fedora Core
- Updating the 3ware Driver Under SuSE
- Updating the 3ware Driver Under FreeBSD
- Updating the Firmware Under Linux and FreeBSD
- Viewing Battery Information
- Testing Battery Capacity
- 3DM 2 Reference
- Troubleshooting
- Appendices
- Index

Error and Notification Messages
www.3ware.com 253
Action
AMCC recommends verifying the unit. See “Starting a Verify Manually” on
page 148.
0043 Backup DCB read error detected
Event Type
Warning
Cause
The controller has detected a latent error in the backup Disk Configuration
Block (DCB).
The 3ware RAID controller checks the backup DCB, even when the primary
DCB is OK. If an error is found, the controller will attempt to correct the error
by reading the primary copy. If the primary copy is valid, the backup DCB
will be rewritten to rectify the errors.
Action
AMCC recommends verifying the unit. See “Starting a Verify Manually” on
page 148.
0044 Battery voltage is normal
Event Type
Information
Cause
The battery pack voltage being monitored by the Battery Backup Unit fell
outside of the acceptable range and then came back within the acceptable
range.
Action
None required
0045 Battery voltage is low
Event Type
Warning