User guide
Table Of Contents
- Title Page
- Table of Contents
- About this User Guide
- Introducing the 3ware® SATA RAID Controller
- Getting Started with Your 3ware RAID Controller
- First-Time RAID Configuration Using 3BM
- Driver Installation
- Driver Installation Under Windows
- Driver Installation Under Linux
- Obtaining 3ware Linux Drivers
- Driver Installation Under Red Hat Linux or Fedora Core 5
- Materials required
- Creating a Red Hat Linux Driver Diskette
- Installing the 3ware Kernel Driver Module while Installing Red Hat Linux on a New Unit
- Installing the 3ware Kernel Driver Module on a Red Hat or Fedora Core Linux System that Boots From a Different Device
- About Variables In the Kernel Driver Module Installation Instructions
- Driver Installation Under SuSE Linux
- Compiling a 3ware Driver for Linux
- Driver Installation Under FreeBSD
- 3ware BIOS Manager 2 (3BM 2) Introduction
- 3DM 2 (3ware Disk Manager) Introduction
- Configuring Your Controller
- Configuring Units
- Configuring a New Unit
- Creating a Hot Spare
- Naming a Unit
- Setting Unit Policies
- Changing An Existing Configuration by Migrating
- Deleting a Unit
- Removing a Unit
- Moving a Unit from One Controller to Another
- Adding a Drive
- Removing a Drive
- Rescanning the Controller
- Maintaining Units
- Checking Unit and Drive Status through 3DM
- About Degraded Units
- About Inoperable Units
- Alarms, Errors, and Other Events
- Background Tasks
- Scheduling Background Tasks
- Locating a Drive by Blinking Its LED
- Maintaining Your Controller
- Determining the Current Version of Your 3ware Driver
- Updating the Firmware and Driver
- Downloading the Driver and Firmware
- Updating the Firmware Through 3DM 2
- Updating the 3ware Driver and Firmware Under Windows
- Using the Update Utility With Multiple Controllers
- Updating the 3ware Driver Under Windows XP
- Updating the 3ware Driver Under Red Hat or Fedora Core
- Updating the 3ware Driver Under SuSE
- Updating the 3ware Driver Under FreeBSD
- Updating the Firmware Under Linux and FreeBSD
- Viewing Battery Information
- Testing Battery Capacity
- 3DM 2 Reference
- Troubleshooting
- Appendices
- Index

Maintenance page
www.3ware.com 205
Maintenance Task Buttons
Below the list of units, a row of task buttons lets you perform maintenance
and configuration tasks related to the unit. Before clicking one of these
buttons, select the appropriate unit.
Verify Unit. Puts the selected unit in verifying mode. If verify scheduling is
enabled on the Scheduling page, the unit will not start actively verifying until
the scheduled time, and the status will indicate “Verify-Paused.” (The Unit
Details page will indicate whether a unit is actively verifying.) If verify
scheduling is not enabled, clicking Verify Unit begins the verification process.
If the unit you selected to verify is a redundant unit, the redundancy of the unit
will be verified. For example it will check parity for a RAID 5 or check data
consistency for a RAID 1. If the unit you checked is not a redundant unit,
verify will do a surface scan of the media. During verification, I/O continues
normally. For RAID 0, single disks, JBODs, and spares, there is only a slight
performance loss. For redundant units, you can set the background task rate
on the Controller Settings page to specify whether more processing time
should be given to verifying or to I/O. For more information, see “About
Verification” on page 146 and “Setting Background Task Rate” on page 155.
While a unit is verifying, the status changes to Verifying and a
Stop Verify
link appears in the right-most column of the Unit Maintenance table.
Rebuild Unit. Replaces a failed drive in a degraded unit with an available
drive and begins rebuilding the RAID. When you select a degraded unit and
click
Rebuild Unit, a dialog box listing available drives appears, so that you
can select the drive you want to use. If the degraded unit has more than one
failed drive (for example, a RAID 10 where both mirrored pairs each have a
failed drive), you will repeat this process a second time.
Warning: Physically removing drives which are not in hotswap carriers can result
in a system hang or may even damage the system and the drive.
Note: If the unit has not previously been initialized and you click Verify Unit, the
initialization process starts. Initialization cannot be halted, so no Stop Verify link
appears. (Initialization can be paused, however, through Scheduling. Initialization
follows the Rebuild schedule, so turning on scheduling for Rebuild will pause
initialization, as well.) For more information about initialization, see “About
Initialization” on page 143.