Error and Notification Messages
www.3ware.com 131
0055 Battery charging started
This message is posted when the Battery Backup Unit starts a battery charge
cycle.
0056 Battery charging completed
This message is posted when the Battery Backup Unit completes a battery
charge cycle.
0057 Battery charging fault
This message is posted when the charger of the Battery Backup Unit has
detected a battery fault during a charge cycle. The Battery Backup Unit
becomes not ready and is unable to backup the 3ware RAID controller.
0058 Battery capacity is below warning level
The measured capacity of the battery is below the warning level. When this
occurs the Battery Backup Unit is still able to backup the 3ware RAID
controller but it signals that the battery pack should be replaced soon.
0059 Battery capacity is below error level
The measured capacity of the battery is below the error level. When this
occurs the Battery Backup Unit becomes not ready and is unable to backup
the 3ware RAID controller. You must replace the battery pack.
005A Battery is present
This message is posted to the host when the Battery Backup Unit detects that
a battery pack has been connected.
005B Battery is not present
This message is posted to the host when the Battery Backup Unit detects that
the battery pack has been removed.
005C Battery is weak
The Battery Backup Unit periodically evaluates the health of the battery and
its ability to backup the 3ware RAID controller in case of a power failure.
This message is posted when the result of the health test is below the warning
threshold. This indicates that the battery pack should be replaced soon