Specifications
Volume
Mute
Power
Fig 6
11
6. Keypad XK1 and Zone Setup
7. EQ Control
The Zone number each keypad XK1 belonging to is decided by which RJ45
connector each keypad connected through Cat-5 cable from JK2 of XK1 to XOi.
The keypads can be used to set specific zone functions. These are for bass and
treble EQ response and source grouping.
To change bass response, press Mute and Source 2 simultaneously and then
release. Press Volume Up/Down keys for desired boost/cut as shown on volume
LEDs, Fig.6. Likewise, changing treble response can be made in the same process,
but it is accessed by pressing Mute and Source 3 together. Once the desired setting
is achieved, press any sources key will release EQ adjust mode.
8. Source Grouping Mode Capability
Sourcing Grouping is a feature that allows multiple zones in an open living space to
always share the same source selection but still retain individual volume control.
This mode forces all zones to same source and allows mute on/off and all zone off
functions to operate all zones in unison.
To engage Source Grouping Mode, press and hold a desired Source button for >5
seconds and release button when all volume indications are turned on. Source
button then turns Amber in color, indicating system is now in Source Grouping
Mode. When the Source Grouping Mode is initiated, the volume in all zones is
defaulted to -30dB.
To cancel Source Grouping Mode, press and hold a Source button from the
initiating zone for >5 seconds and release button when all volume indicators are
turned on. The source button will then turns Red in color.
The XOi system keypads automatically memorize the listening volume when all
zones have been turned off and a zone is turned on again.
Flat +4dB-4dB-6dB-8dB +6dB +8dB