User Guide
When D-01= Premium MPPT
Series Time
< or > 00~23 Hr
00~59 Min
1 Min
When D-01=Battery SOC
< or > 0~100%
1%
※ Battery SOC is only active when terminal BCS is connected with a Shunt
50mV, 500Amp.
D-03: Aux RY1 OFF Condition
z According to 9 selectable modes in D-01, use Constant D-03 to set the condition
to activate the Auxiliary Relay 1 to be OFF.
z The displayed setting range of D-03 will change to less than or greater than (< or
>) depending on if D-02 or D-03 is higher or lower value. This allows setting on
either a rising or falling voltage.
z Once entering the D-03, use UP and DOWN keys to increment and decrement
the values.
Aux RY1 OFF Condition Setting Range of D-03 Setting Unit
When D-01= Solar Voltage
< or > 0~150V/0~250V
0.1V
When D-01=Output Volts
< or > 0~64V
0.1V
When D-01=Battery Volts
< or > 0~64V
0.1V
※ Battery Voltage is only displayed and active when terminal BVS is
connected to the battery.
When D-01=OUT Current
< or > 0~80A
1A
When D-01=BATT Current
< or > -500~500A
1A
※ Battery Current is only active when terminal BCS is connected with a
Shunt 50mV, 500Amp.
※ The values may be positive or negative as this input reads load current as
well as charge current.
When D-01= Premium MPPT
Series Temp.
< or > -20~100℃ 1℃
When D-01=Battery Temp.
< or > -20~100℃ 1℃
※ Battery Temperature is only active when terminal BTS is connected with a
Battery Temperature Sensor (BTS-3).
When D-01= Premium MPPT
Series Time
< or > 00~23 Hr
00~59 Min
1 Min
When D-01=Battery SOC
< or > 0~100%
1%
※ Battery SOC is only active when terminal BCS is connected with a Shunt
50mV, 500Amp.
5-11