User Guide
and will only be active when using an optional 50mv/500amp external shunt.
※ U-13 will only be displayed when the terminal BVS (Battery Voltage Sensing)
is wired to the battery. To show the precise values, an optional 50mv/500amp
external shunt is needed.
U-14: Battery Amp Hours
z This screen displays the battery capacity in AHr (Amp Hours). Battery Amp
Hours will only be visible when terminal BVS (Battery Voltage Sensing) is
connected to the battery and will only be active when using an optional
50mv/500amp external shunt.
※ U-14 will only be displayed when the terminal BVS (Battery Voltage Sensing)
is wired to the battery. To show the precise values, an optional 50mv/500amp
external shunt is needed.
U-15: Battery Temperature
z This screen displays the battery temperature in ℃. Battery Temperature will only
be visible when Battery Voltage Sensor is connected and will only be active
when using a Battery Temperature Sensor (BTS-3).
※ U-15 will only be displayed when the terminal BVS (Battery Voltage Sensing)
is wired to the battery. To show the precise values, a Battery Temperature
Sensor (BTS-3) is needed to be wired to terminal BTS.
U-16: Parallel COMM Status
z This screen displays the communication status between Master unit and Slave
units. U-16 is only displayed when Slave is selected as Premium MPPT Series
Network MODE (F-01).
z When the communication is successful, the screen displays SLAVE UNIT. When
the communication fails, then screen displays NETWORK ERROR.
U-17: Serial Number
z This screen displays the unit serial number. It is useful when contacting Power
Master Technical Support.
5-3