User Guide

Main Menu Group Constant LCD Display Range Unit
Factory
Setting
Remark Page
When D-01=
Premium MPPT Time
00~23 Hr
00~59 Min
1 Min 0 5-11
D-03
When D-01=Battery SOC 0~100 1% 0 5-11
D
D-04 Aux RY1 MIN. ON time
0~23 Hr,
0~59Min
1 Min 0 5-11
Auxiliary Relay 2
E-01 Set Aux Relay 2 Mode
OFF, ON,
Solar Voltage,
Output Volts,
Battery Volts,
OUT Current,
BATT Current,
Temp.
Battery Temp.
Time,
Battery SOC,
Output Volts
OFF 5-12
Aux RY2 ON Condition See Below
See
Below
See
Below
5-12
When E-01= Solar Voltage 0~150/0~250 0.1V 0 5-12
When E-01=Output Volts 0~64 0.1V 0 5-12
When E-01=Battery Volts 0~64 0.1V 0 5-12
When E-01=OUT Current 0~80 1A 0 5-12
When E-01=BATT Current
-500~500 1A 0 5-12
When E-01=Premium MPPT Temp
-20~100
1
0 5-12
When E-01=Battery Temp. -20~100
1
0 5-12
When E-01=
Premium MPPT Time
00~23 Hr
00~59 Min
1 Min 0 5-12
E-02
When E-01=Battery SOC 0~100 1% 0 5-12
AuxRY2 OFF Condition See Below
See
Below
See
Below
5-12
When E-01= Solar Voltage 0~150/0~250 0.1V 0 5-12
When E-01=Output Volts 0~64 0.1V 0 5-12
Programming
E
E-03
When E-01=Battery Volts 0~64 0.1V 0 5-12
4-4