Specifications

contain up to 63 characters.
9) AES Encryption Key Size - Enable/Disable encryption by selecting the
AES encryption key size for the selected network module.
10) AES Encryption Key String - The user shall be able to display, add and
modify the AES encryption string based upon the key size previously
configured for the selected network module.
b. Point Param eters:
1) Point Selection between one and the m axim um number of points in the
control panel.
2) Point Registration to allow system response from a specific physical point
on any one of the expansion modules; On-board, Point expansion
modules (wired or wireless), and Access.
3) W ireless points shall be able to be enrolled in the system via an auto
learn feature.
c. Event Routing Param eters to allow program ming of up to 4 report routing
groups as well as configuration of prim ary and secondary paths.
3. The DACS shall accom m odate connection with up to 8 ACCs, each capable of
displaying custom English text on liquid crystal or vacuum fluorescent (VF) displays.
4. The ACC's shall be capable of displaying point status, arm /disarm status, and carry
out user com m and functions.
5. The ACC can be program med to respond to the entry of any of the specifically
authorized user passcodes.
6. The ACCs shall be able to be configured to control a specific area, or group of areas,
or all areas in the system .
7. The ACCs shall be able to be tem porarily re-addressed to view the status of a remote
area.
8. The ACC's shall be able to provide different audible tones for Intrusion, Fire alarm s,
and system troubles
G. User Passcodes and Authority: Passcodes shall be program m able with authority levels to
allow users to operate any or all areas.
1. Up to 999 different passcodes shall be accomm odated.
2. Up to 399 different passcodes shall be accomm odated.
3. Up to 99 different passcodes shall be accom m odated
4. Up to 32 different passcodes shall be accom m odated.
5. Each passcode shall be 3 to 6 digits (variable) and be assigned a 16-character user
nam e that shall be printed on the local printer and DACR with associated opening and
closing reports from the user.
6. Each passcode shall be 3 to 7 digits (variable).
7. User access to System features and functions shall be configurable based on 14
individually program m able levels of authority assigned to the user passcode.
Additionally, the system shall have the capability to assign to the user passcode, a
different authority level in each of the areas. A service passcode can be assigned to
the servicing agent allowing the agent limited access to system functions.
User-program m able / activated functions include:
a Arm ing the system: All areas, specific area(s) only, perimeter instant, perim eter
delayed, perimeter partial, watch mode, and arm ing the system with a duress
passcode.
b. Disarm ing the system : All areas, specific area(s) only and disarming with a
duress passcode.
c. Viewing system status: Faulted points, event mem ory, bypassed points, area
status and point status.
d. Implem entation functions: Bypass a point, unbypass a point, and reset sensors,
silence bell, activating relays, initiating the rem ote programm ing function locally
to allow program m ing the system from a rem ote location.
e. Testing the system : Local W alk test, Service W alk test, Fire test, send report to
rem ote DACR to check the telephone link, and program ming the tim e and date
for the next test report transm ission.
f. Change system parameters: ACC display brightness, system tim e and date,
and add/delete/change passcodes.