Specifications

b) 4CIF, NTSC: 15 IPS
c) 2CIF, PAL: 25 IPS
d) 2CIF, NTSC: 30 IPS
e) CIF, PAL: 25 IPS
f) CIF, NTSC: 30 IPS
3) Local 4 Channels:
a) 4CIF, PAL: 25 IPS
b) 4CIF, NTSC: 30 IPS
c) 2CIF, PAL: 25 IPS
d) 2CIF, NTSC: 30 IPS
e) CIF, PAL: 25 IPS
f) CIF, NTSC: 30 IPS
4) Remote (network) 16 Channels:
a) CIF, PAL: 6.75 IPS
b) CIF, NTSC: 7.5 IPS
5) Remote (network) 8 Channels:
a) CIF, PAL: 12.5 IPS
b) CIF, NTSC: 15 IPS
10. Display Modes
a. Monitor A: Full, quad, m ulti-screen (live and playback), full sequence, alarm
call-up (live)
b. Monitor B: Full, quad, m ulti-screen, full sequence, alarm call-up (live)
11. Recording Modes
a. Norm al Partition: Continuous recording (with or without overwriting)
b. Event Partition: Input and m otion recording (with or without
12. Mechanical:
a. Dimensions (W xDxH): 355 x 362 x 78 mm (13.9 x 14.2 x 3.1 in)
b. W eight: 4.3 kg (9.46 lb) approx.
13. Environm ental
a. Operating Tem perature: +0°C to +40°C (+32°F to +104°F)
b. Storage Tem perature: -40°C to +70°C (-40°F to +158°F)
c. Operating Humidity: <93% non-condensing
d. Storage Hum idity: <95% non-condensing
PART 3 EXECUTION
A. EXAMINATION
1. Exam ine areas to receive devices and notify adverse conditions affecting installation
or subsequent operation.
2. Do not begin installation until unacceptable conditions are corrected.
3. Non-com pliance with security instructions m ay result in loss of data.
4. Ensure environm ental, m echanical and electrical requirem ents are m et.
B. PREPARATION
1. Protect devices from dam age during construction.
C. INSTALLATION
1. Install devices in accordance with manufacturer's instruction at locations indicated on
the floor drawings plans.
2. Perform installation with qualified service personnel.
3. Install devices in accordance with the National Electrical Code or applicable local
codes.
4. Ensure selected location is secure and offers protection from accidental damage.
5. Location must provide reasonable tem perature and humidity conditions, free from
sources of electrical and electromagnetic interference.
D. FIELD QUALITY CONTROL
1. Test proper operation of all video system devices.
a. Com m unication between recorder and cam eras.
b. Independent operation of alarm s, and cam eras.
2. Test proper operation of software program s.
3. Determ ine and report all problem s to the m anufacturer's custom er service
department.
Page 20