User Manual
Table Of Contents
Model: SP3000T
Revision P1A/01102013
USER MANUAL
SmartPoint SP3000T
3. Observe readings from SP in Ambient Studio
Once awakened, the device will adopt operational status. The SP is now
visible in Ambient Studio. In default configuration, the SP will report
temperature every 15 minutes in a message from the DDI driver DDI(11:1:1)
TMP::TMP102. In the ‘DDI’ tab of Ambient Studio, set the filter to select the ID
of the device. The received queue should display all received DDI(11:1:1)
messages.
If the aforementioned messages are being received, the device has started
correctly and is operational.
If the SP does not report periodically, or sends out messages of DDI type
FLUSHPUSH, it is possible that the device does not have a sufficient
connection with the infrastructure. Use the Ambient Studio ‘Map’ view to
visualize the infrastructure and SP links. When the DDI (3:9)
Network::SmartPoint driver has been enabled, it will periodically PUSH
network link quality information updates. If the reported RSSI values are
approaching to the lower limit ???, either a MR needs to be added to the
network, or the device needs to be moved closer to a MR or GW.
Ambient Systems B.V.
Page 12 of 19
Colosseum 15D • 7521 PV Enschede • The Netherlands
T: +31 88 2624368 • F: +31 88 2624399 • www.ambient-systems.net
KvK: 08122911 • VAT NL: 81297625381
CHECK.TRACK.TRACE.