User's Manual

User Manual
SM3000 OEM module
3 Operating conditions
Table 2: Operating Conditions
Parameter Min Typical Max Units Condition
Operating temperature -40 - 85 °C
4 Electrical Specifications
Table 3: Electrical Specifications
Parameter Min Typical Max Units Condition
Supply voltage 3.3 3.6 3.8 V Applied via VBAT 1 or VBAT 2*
3.0 3.3 3.6 V Applied via VDD**
Current consumption RX - 26.9 - mA Excluding peripherals consumption.***
Current consumption TX - 26.7 - mA Excluding peripherals consumption.***
Current consumption,
overall - - 50 mA
Worst case scenario, radio in RX mode and
all peripherals working.
Sleep current. - 2 4 µA
* The supply voltage can be applied to either VBAT 1 and VBAT 2 or both. Protected for reverse polarity.
** Unprotected for reverse polarity.
*** On board serial flash memory, temperature sensor, LED
5 Radio Section
Table 4: Radio section
Parameter Min Typical Max Units Condition
Frequency Range 2405 - 2475 MHz 15 channels with 5MHz spacing.
Receiver sensitivity -85 dBm PER=1%
Output Power - 1.9 4.6 dBm EIRP, PCB integrated antenna
7/27 Ambient Systems B.V.