Specifications

Economic Anti-frost OFF weekly program running mode
daily program running mode heating program setting lock
program contents solid time mark
2.Rationale:
(1)There are 3 working modes: comfort ,economic and anti-frost 5°C.
(2) There are in total 11 programs:
a. 9 daily programs(P1-P9)
b. weekly program(AU)
c. free program(Fr)
(3) there are 3 running modes for you to select:
a. daily program running mode(D)
b. weekly program running mode(AU)
c. free program running mode(Fr)
(4) every day(24hours) is divided into 48 segments evenly. Every segment will
be filled in with one working mode to combine a daily program or free program.
(All the settings for daily program will be kept in memory by the unit. All the
settings for free program will not be kept in memory and will finally return back
to anti-frost mode after running). Select one daily program (from daily
programs P1-P9) for every day in a week to combine a weekly program.
3. Turn on at the plug and switch on the unit. Press to start the
display.
4. Set time
Press , the date will start to flash. Press or to select date (1-Monday,
2-Tuesday, 3-Wednesday, 4-Thursday, 5-Friday, 6-Saturday, 7-Sunday).
Press again the hour starts to flash. Press to select hours.
Press again, the minutes start to flash. Press to select minute.
Finally confirm it by .
5. Set target temperature
Press & hold (for approximately 3 seconds) the original comfort target
temperature and comfort mark will start to flash (which means you are
setting the comfort target temperature). Press to select a new comfort
target temperature. Press again the original economic target temperature
and economic mark will start to flash (which means you are setting the
economic target temperature). Press to select the new economic target
temperature. Confirm it by pressing .
Note: range of comfort target temperature is 10°C - 50°C. Economic target
temperature minimum: 5°C maximum: 3°C less than the comfort target
temperature. Anti-frost temperature is 5°C which is not adjustable.