User guide
Table Of Contents
- Introduction
- Hardware setup
- Connection to AMARI UE Simbox
- LTE service
- Initial setting
- Create scenario using WebGui
- Run UE scenarios with WebGui
- Create scenario without WebGui
- Downlink and Uplink transfer using iperf
- NB-IOT devices
- Channel simulator
- logging
- Advanced options
- Troubleshooting
Chapter 7: Run UE scenarios with WebGui 24
7.3 Executing scenario tab
Following buttons are available:
• Reset will flush logs
• Retry will start scenario again
• Stop will stop current scenario
• Export will export in a CSV file scenario results
7.4 Example
Let’s try the following exercise:
• 100 UE have to be connected simultaneously.
• 20 UE will connect every second.
• Each UE will stay connected 10s
• Each UE can’t be powered on less than 10s
• Scenario will last 1 minute.
• UE will perform HTTP transfer and pings.
Let’s create a new scenario.
First, we need to estimate the amount of necessary UE.
If we set only 100 UE:
• The first one will connect at t=0s and disconnect at t=10s
• The last one will connect at t=5s (100 UE will take 5s to connect at 20 caps).
• From t=10s, UE will start to disconnect but there will be no non connected remaining UE
to connect again as UE have to stay disconnected at least 10s.
This implies between t=10s and t=20s, total amount of connected UE will decrease to 0 at
t=20s. As a result: