Installation and Operation Guide

7-10 TS-3000i Web Clock Installation & Operation Guide
Table 7-1: Error Messages
Error Message Cause Solution
L0 bA
Discharged FPR
battery.
FPR battery
cable not
connected.
No AC power.
Verify that the battery cable for the FPR
is connected and connect the power
cord to AC source. Allow FPR battery to
recharge for 24 to 48 hours.
E r Pr
General Print Error.
Unlock cover and remove. Press the
Reset button (see Figure 7-9). If the
error clears, try to stamp a card. If the
unit stamps without having the error
message come up again replace the
cover and lock. The configuration is still
programmed in the clock.
E I Pr
Home Sensor Motor,
Carriage Stuck.
Unlock cover and remove. Set
TS-3000i on side with the ribbon side
up. Press the Reset button to reset the
printer carriage and blow air into the
printer platen to remove or dislodge
jammed objects (i.e., staples).
E 2 Pr
Timing Sensor,
Carriage Stuck.
Unlock cover and remove. Set
TS-3000i on side with the ribbon side
up. Press the Reset button to reset the
printer carriage and blow air into the
printer platen to remove or dislodge
jammed objects. If the error reoccurs,
check the wires and cables to verify all
are connected properly.
E 3 Pr / E 4
Pr
Home Sensor,
Carriage Stuck.
Unlock cover and remove. Press the
Reset button to reset the printer
carriage and the time should reappear
on the display. Try to stamp a card
again so you can hear the machine
attempting to stamp. If you hear that the
assembly sounds sluggish or drags,
Amano recommends that the frame be
re-lubricated with either silicone or
white lithium grease. See the following
figure for location. (DO NOT use WD-40
as it will damage the plastic
components.