FPT-40 Installation & Operation Guide  Page 4-9 
Replacing Optical Sensor Lens 
To replace the optical sensor lens: 
1.  If optical sensor lens becomes damaged (scratched) and cannot be 
cleaned, replacement may be necessary. 
2.  Use the replacement [spare] optical sensor lens included with the 
terminal. Remove the spare sensor lens from the protective 
packaging (see figure), using care not to touch the prism. 
4-12 Spare Prism & Packaging 
3.  Disconnect the AC Power Adapter from the bottom of the terminal. 
4.  Disconnect the communication cable (either Ethernet or serial DB9 
connector) 
5.  Loosen and remove the four (4) back plate retaining screws and 
remove the terminal from the wall mounted back plate. 
6.  Place the terminal on a soft surface face down. Located and remove 
the four (4) Phillips Head screws holding the case front cover. There 
will be one screw in each corner on the back of the case. 
7.  After removing the screws, place the terminal right-side up on the 
back of the case and VERY CAREFULLY lift the front cover up. 
8.  The sensor housing must be removed by unscrewing the four (4) 
Phillips head screws holding it down to access the optical sensor 
lens (see figure). 
Prism