Specifications

FPT-40 Installation & Operation Guide Page 4-7
Step 6. From System Opt menu select Adv Option menu, and
press OK.
Step 7. Select Clr Admin Pri, and press OK.
Step 8. Press OK again to confirm, and reset Admin.
Note: Only an administrator will have access to the Adv Opt menu to
reset the privileges. When setting up privileges, always setup an
Admin first before setting up a Supervisor and Enroller. Failure to
do so could result in not being able to get to the menu options for
additional setup changes.
5. Q: When the fingerprint terminal connects serially, and the
sound "ding, ding" occurs?
A: The possible reasons are:
With RS-232 communications, the computer Baud rate may
not match the terminal setting.
With RS-485 communication, two lines of the converter may
be joined.
6. Q: After fingerprint terminal power up, display always shows
"Please try again"?
A: The following reasons could lead to fingerprint sensor problems:
After a lot of use the surface of the fingerprint sensor
becomes dirty, or there are some scratches on it, so the
machine thinks that it is a fingerprint and tried to identify it.
Clean sensor surface [see Cleaning or Replacing the Optical
Sensor].
The fingerprint sensor cable may be loose, or possible