FPT-40 Installation & Operation Guide  Page 4-1 
Chapter 4: FPT-40 Diagnostics 
Running Diagnostics 
In addition to system diagnostics which run automatically every time 
during power up, the FPT-40 Fingerprint terminal has an internal 
diagnostic utility. This utility can be used to verify the correct operation of 
the terminal to help isolate faulty operation. 
To access diagnostics, perform the following: 
1. Press the Menu button and select Options (see figure). 
Menu
 User Manage
 Options
 Sys Info
Figure 4-1 Select Options 
Note:  If no keypad entries are made within a minute, the terminal will 
beep two (2) times and return to the Welcome screen.
2. Press OK to display the Options menu and select Auto Test 
(see Figure 4-2). 
Options
 Comm Opt
 Log Opt
 Auto Test
Figure 4-2 Options Menu with Auto Test Selected 
Note:  If any users have been setup with privileges, you must be a 
user with Admin privileges to access the Auto Test menu. 