Specifications
FPT-40 Installation & Operation Guide Page 4-1
Chapter 4: FPT-40 Diagnostics
Running Diagnostics
In addition to system diagnostics which run automatically every time
during power up, the FPT-40 Fingerprint terminal has an internal
diagnostic utility. This utility can be used to verify the correct operation of
the terminal to help isolate faulty operation.
To access diagnostics, perform the following:
1. Press the Menu button and select Options (see figure).
Menu
User Manage
Options
Sys Info
Figure 4-1 Select Options
Note: If no keypad entries are made within a minute, the terminal will
beep two (2) times and return to the Welcome screen.
2. Press OK to display the Options menu and select Auto Test
(see Figure 4-2).
Options
Comm Opt
Log Opt
Auto Test
Figure 4-2 Options Menu with Auto Test Selected
Note: If any users have been setup with privileges, you must be a
user with Admin privileges to access the Auto Test menu.